Variable speed drive ATV650, 55kW/75HP, 380…480V, IP55

£11,868.54 inc VAT £9,890.45 ex VAT

Description

Detail

Variable speed drive ATV650, 55kW/75HP, 380…480V, IP55. range of product: Altivar Process ATV600 – product or component type: variable speed drive – product specific application: process and utilities – device short name: ATV650 – variant: standard version – product destination: asynchronous motors, synchronous motors – mounting mode: wall mount – IP degree of protection: IP55 conforming to IEC 60529, IP55 conforming to IEC 61800-5-1 – type of cooling: forced convection – motor power kW: 45 kW heavy duty, 55 kW normal duty – motor power hp: 60 hp heavy duty, 75 hp normal duty – line current: 71.8 A 480 V heavy duty, 81.4 A 380 V heavy duty, 84.2 A 480 V normal duty, 97.2 A 380 V normal duty – prospective line Isc: 50 kA – apparent power: 59.7 kVA 480 V heavy duty, 70 kVA 480 V normal duty – continuous output current: 106 A 2.5 kHz normal duty, 87 A heavy duty – maximum transient current: 116.6 A 60 s normal duty, 132 A 60 s heavy duty – asynchronous motor control profile: constant torque standard, optimized torque mode, variable torque standard – synchronous motor control profile: permanent magnet motor, synchronous reluctance motor – output frequency: 0.0001…0.5 kHz – speed drive output frequency: 0.1…599 Hz – nominal switching frequency: 2.5 kHz – switching frequency: 2…8 kHz adjustable, 2.5…8 kHz with derating factor – discrete input logic: 16 preset speeds – communication port protocol: Ethernet, Modbus serial, Modbus TCP – option card: communication module BACnet MS/TP, communication module CANopen daisy chain RJ45 slot A, communication module CANopen screw terminals slot A, communication module CANopen SUB-D 9 slot A, communication module DeviceNet slot A, communication module Ethernet IP/Modbus TCP/MD-Link slot A, communication module Ethernet Powerlink, communication module Modbus TCP/EtherNet/IP slot A, communication module Profibus DP V1 slot A, communication module Profinet slot A, digital and analog I/O extension module slot A/slot B, output relay extension module slot A/slot B.

Specification

  • Integrated breaking resistance : No
  • Supporting protocol for CAN : No
  • Supporting protocol for TCP/IP : Yes
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for KNX : No
  • Supporting protocol for ASI : No
  • Supporting protocol for SUCONET : No
  • Supporting protocol for other bus systems : No
  • Supporting protocol for MODBUS : Yes
  • With optical interface : No
  • Supporting protocol for LON : No
  • Supporting protocol for DeviceNet : Yes
  • 4-quadrant operation possible : Yes
  • Application in domestic- and commercial area permitted : Yes
  • Supporting protocol for INTERBUS : No
  • Application in industrial area permitted : Yes
  • With PC connection : No
  • Supporting protocol for PROFIsafe : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for SafetyBUS p : No
  • Supporting protocol for INTERBUS-Safety : No
  • Supporting protocol for PROFINET IO : Yes
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for EtherNet/IP : Yes
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for PROFINET CBA : No
  • Nominal output current I2N : 106 A
  • Degree of protection (IP) : IP55
  • Number of phases output : 3
  • Mains frequency : 50/60 Hz
  • Relative symmetric net voltage tolerance : 0 %
  • Number of interfaces PROFINET : 0
  • Number of HW-interfaces RS-422 : 0
  • Number of HW-interfaces RS-232 : 0
  • Max. output at linear load at rated output voltage : 55 kW
  • Number of HW-interfaces industrial Ethernet : 1
  • Width : 345 mm
  • Depth : 375 mm
  • Max. output frequency : 500 Hz
  • Number of phases input : 3
  • Number of HW-interfaces USB : 0
  • Relative symmetric net frequency tolerance : 5 %
  • Number of HW-interfaces other : 0
  • Height : 1250 mm
  • Max. output voltage : 480 V
  • Number of HW-interfaces serial TTY : 0
  • Number of HW-interfaces RS-485 : 1
  • Max. output at quadratic load at rated output voltage : 0 kW
  • Number of HW-interfaces parallel : 0
  • Mains voltage : 380 – 480 V
  • With control unit : Yes
  • Supporting protocol for PROFIBUS : Yes