Tesys SkMini Contactor 2 Pole (2 No) AC-3 690V 5A 48V AC Coil

£33.70 inc VAT £28.08 ex VAT

SKU: 2500115976 Category: Tags: , ,

Description

Detail

TeSys SK mini contactor, 2p (2 NO), AC-3, 690 V 5A, 48 V AC coil. range: TeSys – product name: TeSys SK – product or component type: mini contactor – device short name: LC1SKGC – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3 – poles description: 2P – pole contact composition: 2 NO – [Ie] rated operational current: 20 A (<= 50 °C) AC AC-1, 5 A at <= 400 V AC AC-3 – Irms rated making capacity: 50 A AC conforming to IEC 60947, 50 A AC conforming to NF C 63-110 – rated breaking capacity: 40 A at <= 400 V conforming to IEC 60947, 40 A at <= 400 V conforming to NF C 63-110 – [Ui] rated insulation voltage: 690 V for power circuit conforming to BS 5424, 690 V for power circuit conforming to CSA C22.2 No 14, 690 V for power circuit conforming to IEC 60947, 690 V for power circuit conforming to UL 508, 690 V for power circuit conforming to VDE 0110 group C – mounting support: rail – standards: BS 5424, IEC 60947, NF C 63-110, VDE 0660 – product certifications: cULus – connections – terminals: connector 1 cable(s) 0.35…6 mm² – cable stiffness: flexible – with cable end, connector 1 cable(s) 0.5…6 mm² – cable stiffness: flexible – without cable end, connector 1 cable(s) 1.5…6 mm² – cable stiffness: solid, connector 2 cable(s) 0.35…1.5 mm² – cable stiffness: flexible – with cable end, connector 2 cable(s) 0.35…2.5 mm² – cable stiffness: flexible – without cable end, connector 2 cable(s) 1.5…4 mm² – cable stiffness: solid – operating time: 6…8 ms coil de-energisation and NO opening, 7…14 ms coil energisation and NO closing – mechanical durability: 10 Mcycles.

  • · Height: 56mm
  • · Number of Poles: 2P
  • · Range: Tesys Sk
  • · Width: 27mm
  • · Weight: 0.132kg
  • · Depth: 55mm
  • · Normal State Configuration: 2 No

Specification

  • Type of electrical connection of main circuit : Screw connection
  • Voltage type for actuating : AC
  • Rated operation current Ie at AC-3, 400 V : 5 A
  • Number of main contacts as normally open contact : 2
  • Rated operation power at AC-3, 400 V : 2.2 kW
  • Number of auxiliary contacts as normally open contact : 0
  • Rated operation current Ie at AC-1, 400 V : 20 A
  • Number of auxiliary contacts as normally closed contact : 0
  • Number of normally closed contacts as main contact : 0
  • Rated control supply voltage Us at AC 50HZ : 48 – 48 V
  • Rated control supply voltage Us at AC 60HZ : 48 – 48 V
  • Modular version : Yes