Tesys SkMini Contactor 2 Pole (2 No) AC-1 690V 12A 24V DC Coil

£37.92 inc VAT £31.60 ex VAT

SKU: 2500153098 Category: Tags: , ,

Description

Detail

TeSys SK, mini contactor, 2p (2 NO), AC-1, 690 V 12A, 24 V DC coil. product or component type: mini contactor – device short name: LP1SK – contactor application: resistive load – utilisation category: AC-1 – poles description: 2P – pole contact composition: 2 NO – Irms rated making capacity: 66 A at 690 V AC conforming to IEC 60947, 66 A at 690 V AC conforming to NF C 63-110 – rated breaking capacity: 52 A at <= 400 V for power circuit conforming to IEC 60947, 52 A at <= 400 V for power circuit conforming to NF C 63-110 – [Ui] rated insulation voltage: 690 V conforming to BS 5424, 690 V conforming to CSA C22.2 No 14, 690 V conforming to IEC 60947, 690 V conforming to UL 508, 690 V conforming to VDE 0110 group C – mounting support: rail – standards: BS 5424, IEC 60947, NF C 63-110, VDE 0660 – product certifications: CSA, UL – connections – terminals: power circuit : connector 1 cable(s) 0.35…6 mm² – cable stiffness: flexible – with cable end, power circuit : connector 1 cable(s) 0.5…6 mm² – cable stiffness: flexible – without cable end, power circuit : connector 1 cable(s) 1.5…6 mm² – cable stiffness: solid, power circuit : connector 2 cable(s) 0.35…1.5 mm² – cable stiffness: flexible – with cable end, power circuit : connector 2 cable(s) 0.35…2.5 mm² – cable stiffness: flexible – without cable end, power circuit : connector 2 cable(s) 1.5…4 mm² – cable stiffness: solid – operating time: 4…6 ms coil de-energisation and NO opening, 8…12 ms coil energisation and NO closing – mechanical durability: 10 Mcycles.

  • · Height: 56mm
  • · Number of Poles: 2P
  • · Range: Tesys Sk
  • · Width: 27mm
  • · Weight: 0.132kg
  • · Depth: 55mm
  • · Normal State Configuration: 2 No

Specification

  • Type of electrical connection of main circuit : Screw connection
  • Voltage type for actuating : DC
  • Rated operation power at AC-4, 400 V : 0 kW
  • Rated operation current Ie at AC-4, 400 V : 0 A
  • Rated operation current Ie at AC-1, 400 V : 12 A
  • Number of main contacts as normally open contact : 2
  • Rated operation current Ie at AC-3, 400 V : 6 A
  • Rated operation power at AC-3, 400 V : 2.2 kW
  • Number of auxiliary contacts as normally open contact : 0
  • Number of auxiliary contacts as normally closed contact : 0
  • Number of normally closed contacts as main contact : 0
  • Rated control supply voltage Us at AC 50HZ : 0 – 0 V
  • Rated control supply voltage Us at AC 60HZ : 0 – 0 V
  • Modular version : No
  • Rated control supply voltage Us at DC : 24 – 24 V