Description
Detail
TeSys LE, enclosed DOL starter, 9A, 400 V AC coil. range: TeSys – product name: TeSys LE – device short name: LE1D – device application: standard – utilisation category: AC-3 – device composition: contactor, thermal overload relay to be ordered separately – control type: push-button start green I, push-button stop/reset red O.
- · Height: 166mm
- · Width: 88mm
- · Weight: 0.92kg
- · Depth: 128mm
Specification
Rail mounting possible : No
Supporting protocol for TCP/IP : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for DeviceNet : No
Supporting protocol for other bus systems : No
External reset possible : No
Supporting protocol for INTERBUS : No
Supporting protocol for LON : No
Suitable for emergency stop : No
Supporting protocol for SUCONET : No
Supporting protocol for MODBUS : No
Supporting protocol for Data-Highway : No
Supporting protocol for SERCOS : No
Supporting protocol for ASI : No
Supporting protocol for DeviceNet Safety : No
With short-circuit release : No
With fuse : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFINET IO : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for PROFIsafe : No
Temperature compensated overload protection : No
Depth : 128.5 mm
Type of electrical connection of main circuit : Screw connection
Voltage type for actuating : AC
Type of electrical connection for auxiliary- and control current circuit : Screw connection
Kind of motor starter : Direct starter
Rated conditional short-circuit current, type 1, 600 Y/347 V : 0 A
Rated conditional short-circuit current, type 1, 480 Y/277 V : 0 A
Rated conditional short-circuit current, type 2, 230 V : 0 A
Rated conditional short-circuit current, type 2, 400 V : 0 A
Rated power, 460 V, 60 Hz, 3-phase : 0 kW
Height : 166 mm
Rated power, 575 V, 60 Hz, 3-phase : 0 kW
Number of command positions : 1
Rated operation power at AC-3, 400 V : 4 kW
Degree of protection (IP) : IP65
Ambient temperature, upper operating limit : 40 °C
Width : 88 mm
Number of auxiliary contacts as normally closed contact : 0
Rated operation current Ie : 9 A
Number of auxiliary contacts as normally open contact : 0
Number of indicator lights : 0
Rated operation power at AC-3, 230 V, 3-phase : 2.2 kW
Rated operation current at AC-3, 400 V : 9 A
Rated control supply voltage Us at AC 50HZ : 400 – 400 V
Rated control supply voltage Us at AC 60HZ : 400 – 400 V
Overload release current setting : 0 – 0 A
With transformer : No