TeSys LE, enclosed DOL starter, 35A, 400 V AC coil

£928.22 inc VAT £773.52 ex VAT

Description

Detail

TeSys LE, enclosed DOL starter, 35A, 400 V AC coil. range: TeSys – product name: TeSys LE – device short name: LE4D – device application: standard – material: polycarbonate – utilisation category: AC-3 – device composition: contactor, fuse disconnector, thermal overload relay ordered separately – motor power kW: 15 kW at 380/400 V AC 50/60 Hz, 15 kW at 415 V AC 50/60 Hz, 15 kW at 440 V AC 50/60 Hz, 18.5 kW at 500 V AC 50/60 Hz, 18.5 kW at 660/690 V AC 50/60 Hz, 7.5 kW at 220/230 V AC 50/60 Hz – control type: push-button start green I, push-button stop/reset red O.

Specification

  • With fuse : Yes
  • Supporting protocol for ASI : No
  • Supporting protocol for MODBUS : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for SUCONET : No
  • External reset possible : No
  • Suitable for emergency stop : No
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for INTERBUS-Safety : No
  • Supporting protocol for other bus systems : No
  • Rail mounting possible : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for LON : No
  • Supporting protocol for PROFINET CBA : No
  • With short-circuit release : Yes
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for SafetyBUS p : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for PROFIsafe : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for EtherNet/IP : No
  • Temperature compensated overload protection : No
  • Number of command positions : 2
  • Degree of protection (IP) : IP65
  • Voltage type for actuating : AC
  • Type of electrical connection for auxiliary- and control current circuit : Screw connection
  • Depth : 175.5 mm
  • Kind of motor starter : Direct starter
  • Number of auxiliary contacts as normally open contact : 0
  • Number of indicator lights : 0
  • Rated operation power at AC-3, 400 V : 15 kW
  • Height : 348 mm
  • Rated operation current Ie : 35 A
  • Width : 217 mm
  • Type of electrical connection of main circuit : Screw connection
  • Rated operation current at AC-3, 400 V : 35 A
  • Ambient temperature, upper operating limit : 40 °C
  • Number of auxiliary contacts as normally closed contact : 0
  • Rated control supply voltage Us at AC 50HZ : 400 – 400 V
  • Rated operation power at AC-3, 230 V, 3-phase : 7.5 kW
  • Rated control supply voltage Us at AC 60HZ : 400 – 400 V
  • With transformer : No
  • Supporting protocol for PROFIBUS : No
  • Supporting protocol for CAN : No
  • Supporting protocol for INTERBUS : No