Description
Detail
TeSys LE, enclosed DOL starter, 1,8…2,6A, 415 V AC coil. range: TeSys – product name: TeSys LE – device short name: LE1M – device application: standard – utilisation category: AC-3 – device composition: contactor, earth terminal, neutral terminal, thermal overload relay – motor power kW: 0.37 kW at 220/230 V AC 50/60 Hz, 0.37 kW at 240 V AC 50/60 Hz, 0.75 kW at 415 V AC 50/60 Hz, 1.1 kW at 380/400 V AC 50/60 Hz – control type: push-button start green I, push-button stop/reset red O.
Specification
Rail mounting possible : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for TCP/IP : No
Supporting protocol for ASI : No
Supporting protocol for MODBUS : No
Supporting protocol for Data-Highway : No
Supporting protocol for INTERBUS-Safety : No
External reset possible : No
Suitable for emergency stop : No
Supporting protocol for DeviceNet : No
Supporting protocol for SUCONET : No
Supporting protocol for other bus systems : No
With transformer : No
Supporting protocol for LON : No
Supporting protocol for SERCOS : No
With fuse : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
With short-circuit release : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for PROFINET IO : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for EtherNet/IP : No
Temperature compensated overload protection : Yes
Rated conditional short-circuit current, type 2, 230 V : 0 A
Degree of protection (IP) : IP65
Voltage type for actuating : AC
Type of electrical connection for auxiliary- and control current circuit : Screw connection
Kind of motor starter : Direct starter
Release class : CLASS 10 A
Rated operation power at AC-3, 230 V, 3-phase : 0.37 kW
Rated conditional short-circuit current, type 1, 600 Y/347 V : 0 A
Rated power, 460 V, 60 Hz, 3-phase : 0 kW
Height : 160 mm
Number of command positions : 1
Rated conditional short-circuit current, type 2, 400 V : 0 A
Rated conditional short-circuit current, type 1, 480 Y/277 V : 0 A
Depth : 108 mm
Type of electrical connection of main circuit : Screw connection
Rated operation power at AC-3, 400 V : 1.1 kW
Rated power, 575 V, 60 Hz, 3-phase : 0 kW
Ambient temperature, upper operating limit : 40 °C
Width : 78 mm
Number of auxiliary contacts as normally open contact : 0
Rated operation current Ie : 2.6 A
Number of auxiliary contacts as normally closed contact : 0
Number of indicator lights : 0
Rated operation current at AC-3, 400 V : 2.6 A
Rated control supply voltage Us at AC 50HZ : 415 – 415 V
Rated control supply voltage Us at AC 60HZ : 415 – 415 V
Overload release current setting : 1.8 – 2.6 A