TeSys K reversing contactor, 3p, AC-3 <= 440 V 6A, 1 NC, 24 V DC coil

£152.11 inc VAT £126.76 ex VAT

SKU: 2500658601 Category: Tags: , ,

Description

Detail

TeSys K reversing contactor, 3p, AC-3 <= 440 V 6A, 1 NC, 24 V DC coil. range: TeSys – product name: TeSys K – device short name: LP2K – device application: control – contactor application: motor control – utilisation category: AC-3, AC-4 – device presentation: preassembled with reversing power busbar – poles description: 3P – pole contact composition: 3 NO – [Ue] rated operational voltage: <= 690 V AC 50/60 Hz for signalling circuit, 690 V AC 50/60 Hz for power circuit – motor power kW: 1.5 kW at 220…230 V AC 50/60 Hz, 2.2 kW at 380…415 V AC 50/60 Hz, 3 kW at 440 V AC 50/60 Hz, 3 kW at 480 V AC 50/60 Hz, 3 kW at 500…600 V AC 50/60 Hz, 3 kW at 660…690 V AC 50/60 Hz – auxiliary contact composition: 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 50 °C for signalling circuit, 20 A at <= 50 °C for power circuit – Irms rated making capacity: 110 A AC for power circuit conforming to IEC 60947, 110 A AC for power circuit conforming to NF C 63-110, 110 A AC for signalling circuit conforming to IEC 60947 – rated breaking capacity: 110 A at 220…230 V conforming to IEC 60947, 110 A at 380…400 V conforming to IEC 60947, 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 70 A at 660…690 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947 – [Icw] rated short-time withstand current: 110 A 100 ms signalling circuit, 20 A <= 50 °C >= 15 min power circuit, 40 A <= 50 °C 3 min power circuit, 45 A <= 50 °C 1 min power circuit, 60 A <= 50 °C 30 s power circuit, 80 A <= 50 °C 10 s power circuit, 80 A 1 s signalling circuit, 85 A <= 50 °C 5 s power circuit, 90 A <= 50 °C 1 s power circuit, 90 A 500 ms signalling circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660, 25 A aM for power circuit, 25 A gG at <= 440 V for power circuit – [Ui] rated insulation voltage: 600 V for power circuit conforming to CSA C22.2 No 14, 600 V for power circuit conforming to UL 508, 600 V for signalling circuit conforming to CSA C22.2 No 14, 600 V for signalling circuit conforming to UL 508, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-5-1 – interlocking type: mechanical – mounting support: plate, rail – standards: BS 5424, IEC 60947, NF C 63-110, VDE 0660 – product certifications: CSA, UL – operating time: 10 ms coil de-energisation and NO opening, 30…40 ms coil energisation and NO closing – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 5 Mcycles.

Specification

  • Function : Reversing safety
  • Type of electrical connection of main circuit : PCB connection
  • Voltage type for actuating : DC
  • Degree of protection (IP) : IP20
  • Rated operation current Ie at AC-3, 400 V : 6 A
  • Rated operation power at AC-3, 400 V : 2.2 kW
  • Rated control supply voltage Us at DC : 24 – 24 V