TeSys D contactor S207, 4p (4NO) AC-1 40A <=440V, coil 110V DC
£296.21 inc VAT £246.84 ex VAT
Description
Detail
TeSys D contactor S207, 4p (4NO) AC-1 40A <=440V, coil 110V DC. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: resistive load – utilisation category: AC-1 – poles description: 4P – pole contact composition: 4 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – [Ie] rated operational current: 25 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit – coil type: standard – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 40 A at <= 60 °C for power circuit – Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A <= 40 °C 1 min power circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 240 A <= 40 °C 10 s power circuit, 380 A <= 40 °C 1 s power circuit, 50 A <= 40 °C 10 min power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at <= 690 V coordination type 2 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit – [Ui] rated insulation voltage: 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – power dissipation per pole: 1.25 W AC-3, 3.2 W AC-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 60947-4-1, DIN 5510-2, EN 45545 R22 HL3, EN 45545 R26 HL3, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1 – product certifications: CCC, CSA, EAC, IEC, UL – connections – terminals: control circuit : lugs-ring terminals – external diameter: 8 mm, power circuit : lugs-ring terminals – external diameter: 9 mm – tightening torque: control circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver Philips No 2 screw : M3.5, power circuit : 1.8 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm screw : M3.5, power circuit : 1.8 N.m – on lugs-ring terminals – with screwdriver Philips No 2 screw : M3.5 – operating time: 16…32 ms opening, 55…75 ms closing – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1.