TeSys D contactor S207, 3p (3NO) AC-3 25A <=440V, coil 110V DC low

£249.61 inc VAT £208.01 ex VAT

SKU: 2500382643 Category: Tags: , ,

Description

Detail

TeSys D contactor S207, 3p (3NO) AC-3 25A <=440V, coil 110V DC low. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3 – poles description: 3P – pole contact composition: 3 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – [Ie] rated operational current: 25 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit – motor power kW: 11 kW at 380…400 V AC 50 Hz, 11 kW at 415 V AC 50 Hz, 11 kW at 440 V AC 50 Hz, 15 kW at 500 V AC 50 Hz, 15 kW at 660…690 V AC 50 Hz, 5.5 kW at 220…230 V AC 50 Hz – motor power hp: 15 hp at 460/480 V AC 60 Hz for 3 phases motors, 2 hp at 115 V AC 60 Hz for 1 phase motors, 20 hp at 575/600 V AC 60 Hz for 3 phases motors, 3 hp at 230/240 V AC 60 Hz for 1 phase motors, 7.5 hp at 200/208 V AC 60 Hz for 3 phases motors, 7.5 hp at 230/240 V AC 60 Hz for 3 phases motors – coil type: low consumption – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 40 A at <= 60 °C for power circuit – Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 450 A at 440 V for power circuit conforming to IEC 60947 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A <= 40 °C 1 min power circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 240 A <= 40 °C 10 s power circuit, 380 A <= 40 °C 1 s power circuit, 50 A <= 40 °C 10 min power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 40 A gG at <= 690 V coordination type 2 for power circuit, 63 A gG at <= 690 V coordination type 1 for power circuit – [Ui] rated insulation voltage: 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – electrical durability: 1.4 Mcycles 40 A AC-1 at Ue <= 440 V, 1.65 Mcycles 25 A AC-3 at Ue <= 440 V – power dissipation per pole: 1.25 W AC-3, 3.2 W AC-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 60947-4-1, DIN 5510-2, EN 45545 R22 HL3, EN 45545 R26 HL3, EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1 – product certifications: CCC, CSA, EAC, IEC, UL – connections – terminals: control circuit : lugs-ring terminals – external diameter: 8 mm, power circuit : lugs-ring terminals – external diameter: 12 mm – tightening torque: control circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.7 N.m – on lugs-ring terminals – with screwdriver Philips No 2 screw : M3.5, power circuit : 2.5 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm screw : M4, power circuit : 2.5 N.m – on lugs-ring terminals – with screwdriver Philips No 2 screw : M4 – operating time: 16…32 ms opening, 55…75 ms closing – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1.

Specification

  • Voltage type for actuating : DC
  • Number of auxiliary contacts as normally open contact : 1
  • Number of auxiliary contacts as normally closed contact : 1
  • Number of main contacts as normally open contact : 3
  • Rated operation power at AC-3, 400 V : 11 kW
  • Rated operation current Ie at AC-1, 400 V : 40 A
  • Rated operation current Ie at AC-3, 400 V : 25 A
  • Rated control supply voltage Us at DC : 110 – 110 V
  • Modular version : No