TeSys D contactor, 4p(4 NO), AC-1, <= 440 V 80A, 24 V DC standard coil

£852.18 inc VAT £710.15 ex VAT

SKU: 2500381028 Category: Tags: , ,

Description

Detail

TeSys D contactor, 4p(4 NO), AC-1, <= 440 V 80A, 24 V DC standard coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: resistive load – utilisation category: AC-1 – poles description: 4P – pole contact composition: 4 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 80 A at <= 60 °C for power circuit – Irms rated making capacity: 1000 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 110 A <= 40 °C 10 min power circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 260 A <= 40 °C 1 min power circuit, 520 A <= 40 °C 10 s power circuit, 900 A <= 40 °C 1 s power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 125 A gG at <= 690 V coordination type 1 for power circuit, 125 A gG at <= 690 V coordination type 2 for power circuit – [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : spring terminals 1 cable(s) 2.5 mm² – cable stiffness: flexible – without cable end, control circuit : spring terminals 2 cable(s) 2.5 mm² – cable stiffness: flexible – without cable end, power circuit : spring clamp terminal 1 cable(s) 1…35 mm² – cable stiffness: flexible – with cable end, power circuit : spring clamp terminal 1 cable(s) 1…35 mm² – cable stiffness: flexible – without cable end, power circuit : spring clamp terminal 1 cable(s) 1…35 mm² – cable stiffness: solid – without cable end, power circuit : spring clamp terminal 2 cable(s) 1…25 mm² – cable stiffness: flexible – with cable end, power circuit : spring clamp terminal 2 cable(s) 1…25 mm² – cable stiffness: flexible – without cable end, power circuit : spring clamp terminal 2 cable(s) 1…25 mm² – cable stiffness: solid – without cable end – tightening torque: power circuit : 5 N.m – on screw clamp terminals – cable 2.5…25 mm² hexagonal 4 mm, power circuit : 8 N.m – on screw clamp terminals – cable 25…35 mm² hexagonal 4 mm – operating time: 16…24 ms opening, 42.5…57.5 ms closing – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 10 Mcycles.

Specification

  • Type of electrical connection of main circuit : Spring clamp connection
  • Voltage type for actuating : DC
  • Rated operation current Ie at AC-4, 400 V : 0 A
  • Rated operation power at AC-4, 400 V : 0 kW
  • Number of auxiliary contacts as normally open contact : 1
  • Number of auxiliary contacts as normally closed contact : 1
  • Number of main contacts as normally open contact : 4
  • Rated operation power at AC-3, 400 V : 30 kW
  • Rated operation current Ie at AC-3, 400 V : 65 A
  • Rated operation current Ie at AC-1, 400 V : 80 A
  • Rated control supply voltage Us at AC 50HZ : 0 – 0 V
  • Number of normally closed contacts as main contact : 0
  • Rated control supply voltage Us at DC : 24 – 24 V
  • Rated control supply voltage Us at AC 60HZ : 0 – 0 V
  • Modular version : No