TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 150A, 220 V DC standard co

£1,158.32 inc VAT £965.27 ex VAT

SKU: 2500658443 Category: Tags: , ,

Description

Detail

TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 150A, 220 V DC standard coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3, AC-4 – poles description: 3P – pole contact composition: 3 NO – [Ue] rated operational voltage: <= 1000 V AC 25…400 Hz for power circuit, <= 300 V DC for power circuit – [Ie] rated operational current: 150 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit – motor power kW: 100 kW at 660…690 V AC 50/60 Hz AC-3, 22 kW at 400 V AC 50/60 Hz AC-4, 40 kW at 220…230 V AC 50/60 Hz AC-3, 75 kW at 1000 V AC 50/60 Hz AC-3, 75 kW at 380…400 V AC 50/60 Hz AC-3, 80 kW at 415…440 V AC 50/60 Hz AC-3, 90 kW at 500 V AC 50/60 Hz AC-3 – motor power hp: 100 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 125 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 40 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 50 hp at 230/240 V AC 50/60 Hz for 3 phases motors – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 1660 A at 440 V for power circuit conforming to IEC 60947, 250 A DC for signalling circuit conforming to IEC 60947-5-1 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A 500 ms signalling circuit, 1200 A <= 40 °C 10 s power circuit, 140 A 100 ms signalling circuit, 1400 A <= 40 °C 1 s power circuit, 250 A <= 40 °C 10 min power circuit, 580 A <= 40 °C 1 min power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 250 A gG at <= 690 V coordination type 2 for power circuit, 315 A gG at <= 690 V coordination type 1 for power circuit – [Ui] rated insulation voltage: 1000 V for power circuit conforming to IEC 60947-4-1, 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for signalling circuit conforming to IEC 60947-1 – electrical durability: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V – power dissipation per pole: 13.5 W AC-3, 24 W AC-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : lugs-ring terminals – external diameter: 8 mm, power circuit : bars 1 5 x 25 mm, power circuit : lugs-ring terminals – external diameter: 25 mm – tightening torque: control circuit : 1.2 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.2 N.m – on lugs-ring terminals – with screwdriver Philips No 2 screw : M3.5, power circuit : 12 N.m – on bars hexagonal 13 mm screw : M8, power circuit : 12 N.m – on lugs-ring terminals hexagonal 13 mm screw : M8 – operating time: 20…35 ms closing, 40…75 ms opening – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 8 Mcycles.

Specification

  • Voltage type for actuating : DC
  • Number of auxiliary contacts as normally open contact : 1
  • Number of auxiliary contacts as normally closed contact : 1
  • Number of main contacts as normally open contact : 3
  • Rated operation current Ie at AC-3, 400 V : 150 A
  • Rated operation power at AC-3, 400 V : 75 kW
  • Rated operation power at AC-4, 400 V : 22 kW
  • Number of normally closed contacts as main contact : 0
  • Rated operation current Ie at AC-1, 400 V : 200 A
  • Rated control supply voltage Us at DC : 220 – 220 V
  • Modular version : No