TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 12A, 48 V AC coil

£89.70 inc VAT £74.75 ex VAT

SKU: 2500876375 Category: Tags: , ,

Description

Detail

TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 12A, 48 V AC coil. range: TeSys – product name: TeSys D – product or component type: contactor – device short name: LC1D – contactor application: motor control, resistive load – utilisation category: AC-1, AC-3, AC-4 – poles description: 3P – pole contact composition: 3 NO – [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25…400 Hz for power circuit – [Ie] rated operational current: 12 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 16 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit – motor power kW: 3 kW at 220…230 V AC 50/60 Hz AC-3, 3.7 kW at 400 V AC 50/60 Hz AC-4, 5.5 kW at 380…400 V AC 50/60 Hz AC-3, 5.5 kW at 415…440 V AC 50/60 Hz AC-3, 7.5 kW at 500 V AC 50/60 Hz AC-3, 7.5 kW at 660…690 V AC 50/60 Hz AC-3 – motor power hp: 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors, 10 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 2 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 3 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 3 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors – auxiliary contact composition: 1 NO + 1 NC – overvoltage category: III – [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 16 A at <= 60 °C for power circuit – Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A at 440 V for power circuit conforming to IEC 60947, 250 A DC for signalling circuit conforming to IEC 60947-5-1 – [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 105 A <= 40 °C 10 s power circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 210 A <= 40 °C 1 s power circuit, 30 A <= 40 °C 10 min power circuit, 61 A <= 40 °C 1 min power circuit – associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at <= 690 V coordination type 2 for power circuit, 40 A gG at <= 690 V coordination type 1 for power circuit – [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 – electrical durability: 0.8 Mcycles 25 A AC-1 at Ue <= 440 V, 2 Mcycles 12 A AC-3 at Ue <= 440 V – power dissipation per pole: 0.36 W AC-3, 1.56 W AC-1 – protective cover: with – mounting support: plate, rail – standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 – product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL – connections – terminals: control circuit : spring terminals 1 cable(s) 2.5 mm² – cable stiffness: flexible – without cable end, control circuit : spring terminals 2 cable(s) 2.5 mm² – cable stiffness: flexible – without cable end, power circuit : spring terminals 1 cable(s) 2.5 mm² – cable stiffness: flexible – without cable end, power circuit : spring terminals 2 cable(s) 2.5 mm² – cable stiffness: flexible – without cable end – operating time: 12…22 ms closing, 4…19 ms opening – safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 – mechanical durability: 15 Mcycles.

Specification

  • Type of electrical connection of main circuit : Spring clamp connection
  • Voltage type for actuating : AC
  • Number of normally closed contacts as main contact : 0
  • Rated operation current Ie at AC-3, 400 V : 12 A
  • Number of auxiliary contacts as normally open contact : 1
  • Number of auxiliary contacts as normally closed contact : 1
  • Number of main contacts as normally open contact : 3
  • Rated operation power at AC-4, 400 V : 3.7 kW
  • Rated operation power at AC-3, 400 V : 5.5 kW
  • Rated operation current Ie at AC-1, 400 V : 25 A
  • Rated control supply voltage Us at AC 50HZ : 48 – 48 V
  • Rated control supply voltage Us at AC 60HZ : 48 – 48 V
  • Modular version : No