Description
Detail
Schneider non reversing power base applicable for motors with auxiliary contacts (1NO + 1NC)
- · Suitable for isolation
- · Screw clamp terminals: 1 – 10mm² (rigid/flexible cables & with/without cable ends)
- · Operating rate: 60 cyc/mn
- · Conventional free air thermal current: 32A
- · Tightening torque: 0.8-1.2/ 1.9-2.5Nm (control/power circuit)
- · Shock resistance: 10-15gn (open/closed)
- · Vibration resistance: 2-4gn (open/closed)
- · Mechanical durability: 15000000 cycles
- · IP20/40 Degree of protection
- · Ambient temperature: -25°C to 60°C
Specification
Supporting protocol for other bus systems : No
Rated control supply voltage Us at DC : 110 – 220 V
Supporting protocol for Data-Highway : No
Supporting protocol for TCP/IP : No
Supporting protocol for MODBUS : No
Supporting protocol for ASI : No
Supporting protocol for PROFIBUS : No
Supporting protocol for INTERBUS : No
Supporting protocol for CAN : No
Supporting protocol for LON : No
Supporting protocol for DeviceNet : No
Supporting protocol for SERCOS : No
Supporting protocol for SUCONET : No
Rated control supply voltage Us at AC 60HZ : 110 – 240 V
Supporting protocol for EtherNet/IP : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for Foundation Fieldbus : No
Rail mounting possible : Yes
Supporting protocol for DeviceNet Safety : No
Supporting protocol for INTERBUS-Safety : No
With short-circuit release : Yes
Supporting protocol for PROFIsafe : No
Supporting protocol for PROFINET IO : No
Supporting protocol for SafetyBUS p : No
Temperature compensated overload protection : No
Rated operation current at AC-3, 400 V : 0 A
Degree of protection (IP) : IP40
Voltage type for actuating : AC/DC
Kind of motor starter : Direct starter
Number of auxiliary contacts as normally open contact : 1
Rated operation power at AC-3, 230 V, 3-phase : 0 kW
Rated conditional short-circuit current, type 1, 600 Y/347 V : 0 A
Rated conditional short-circuit current, type 2, 230 V : 0 A
Rated conditional short-circuit current, type 1, 480 Y/277 V : 0 A
Rated conditional short-circuit current, type 2, 400 V : 0 A
Number of auxiliary contacts as normally closed contact : 1
Rated power, 460 V, 60 Hz, 3-phase : 0 kW
Height : 145 mm
Type of electrical connection of main circuit : Screw connection
Height : 145 mm
Rated operation power at AC-3, 400 V : 15 kW
Rated power, 575 V, 60 Hz, 3-phase : 0 kW
Depth : 126 mm
Depth : 126 mm
Rated operation current Ie : 32 A
Width : 45 mm
Weight : 865 g
Ambient temperature, upper operating limit : 70 °C
Width : 45 mm
Rated control supply voltage Us at AC 50HZ : 110 – 240 V
Overload release current setting : 0 – 0 A