Description
Detail
Standard Network Interface Module STB, Profibus DP, 9,6 kbit/s. product or component type: standard Network Interface Module – integrated connection type: Profibus DP conforming to DIN 19245 part 1 and 3 8-way female (RS232 port), Profibus DP conforming to DIN 19245 part 1 and 3 9-way female RS485 SUB-D 1 twisted shielded pair (bus), Profibus DP conforming to DIN 19245 part 1 and 3 HE-13 (RS232 port) – number of segments: 1 primary, maximum 6 extensions – number of slave: 125 – transmission rate: 12 Mbit/s for bus length of 0…200 m, 12 Mbit/s for bus length of 0…800 m with 3 repeaters, 9.6 kbit/s for bus length of 0…1200 m, 9.6 kbit/s for bus length of 0…4800 m with 3 repeaters – structure type: industrial field bus DP V.0.
Specification
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for SUCONET : No
System accessory : Yes
Appendant operation agent (Ex ia) : No
Front build in possible : No
Supporting protocol for Data-Highway : No
Wall mounting/direct mounting : No
Rack-assembly possible : Yes
Supporting protocol for EtherNet/IP : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for DeviceNet Safety : No
Radio standard WLAN 802.11 : No
Supporting protocol for SERCOS : No
Supporting protocol for PROFINET IO : No
Supporting protocol for SafetyBUS p : No
Rail mounting possible : Yes
Radio standard Bluetooth : No
Fieldbus connection over separate bus coupler possible : Yes
Appendant operation agent (Ex ib) : No
Radio standard UMTS : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFIsafe : No
Radio standard GPRS : No
Radio standard GSM : No
IO link master : No
Suitable for safety functions : Yes
Voltage type of supply voltage : DC
Performance level acc. EN ISO 13849-1 : None
SIL according to IEC 61508 : None
Category according to EN 954-1 : 1
Degree of protection (IP) : IP20
Explosion safety category for gas : ATEX gas-ex-protection, Cat. 3G
Width : 128.3 mm
Height : 40 mm
Supply voltage DC : 24 – 24 V
Depth : 70 mm
Supply voltage AC 60 Hz : 0 – 0 V
Supply voltage AC 50 Hz : 0 – 0 V
Explosion safety category for dust : None
Supporting protocol for KNX : No
Supporting protocol for CAN : No
Supporting protocol for MODBUS : No
Supporting protocol for other bus systems : No
Supporting protocol for INTERBUS : No
With potential separation : Yes
Supporting protocol for TCP/IP : No
Supporting protocol for ASI : No
Supporting protocol for PROFIBUS : Yes
Supporting protocol for DeviceNet : No
Supporting protocol for LON : No