Soft Starter S6, 145 A, 150 HP/575 V, 50 Degrees, 400-600 V AC, 115 V AC

£2,697.82 inc VAT £2,248.18 ex VAT

SKU: 1050443336 Category: Tags: ,

Description

Detail

SIRIUS soft starter S6 145 A, 150 hp/575 V, 50 °C 400-600 V AC, 115 V AC spring-type terminals Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5056-2AB15<< Soft starter SIRIUS 3RW40 for standard applications for the soft starting and ramp-down of three-phase asynchronous motors. Soft starting, reduction of current peaks, prevention of supply voltage fluctuations during startup, reduction of load on the power supply network, reduction of mechanical load in the drive, considerable saving of space and wiring compared to star-delta (wye-delta) starters and frequency converters, maintenance-free switching and extremely easy handling. The integrated bypass allows a very compact construction and ensures low heat dissipation in the control cabinet. Intelligent monitoring functions protect the soft starter against overheating and the motor against overload. In addition, you can limit the current during startup to a settable maximum value. Worldwide approvals (e.g. IEC and UL/CSA), also for applications in hazardous areas (ATEX or IEC Ex). The 3RW soft starters are available for supply systems up to 690 V in a wide performance range with different control supply voltages and all with both screw and spring-loaded terminals. For the 3RW30/40 there are additional versions with 24 V control supply voltage. Some of the 3RW40 up to size S3, and all 3RW44 units also offer thermistor motor protection. Using the optional remote reset module, you can quickly and easily clear faults from a remote location. Simple, efficient and always up to date – SIRIUS modular system.

Specification

  • Rated control supply voltage Us at AC 50HZ : 115 – 115 V
  • Torque control : No
  • Internal bypass : Yes
  • With display : No
  • Rated operating voltage Ue : 400 – 600 V
  • Integrated motor overload protection : Yes
  • Rated control supply voltage Us at DC : – V
  • Rated control supply voltage Us at AC 60HZ : 115 – 115 V
  • Rated power three-phase motor, inside delta, at 400 V : – kW
  • Degree of protection (IP) : IP00
  • Rated power three-phase motor, inside delta, at 230 V : – kW
  • Rated power three-phase motor, inline, at 400 V : 90000 kW
  • Rated power three-phase motor, inline, at 230 V : – kW
  • Rated operation current Ie at 40 °C Tu : 162 A
  • Rated surrounding temperature without derating : 40 °C
  • Function : Single direction
  • Voltage type for actuating : AC