Soft Starter At 500 V, 40 Degrees, Standard: 162 A, 110 KW, Root Of 3: 281 A, 200 KW

£7,660.66 inc VAT £6,383.88 ex VAT

SKU: 1050443427 Category: Tags: ,

Description

Detail

SIRIUS soft starter Values at 500 V, 40 °C standard: 162 A, 110 kW Inside-delta: 281 A, 200 kW 400-600 V AC, 230 V AC Screw terminals Successor is SIRIUS 3RW5, Preferred successor type is >>3RW5536-6HA16<< Soft starter SIRIUS 3RW44 for high-feature applications for the soft starting and ramp-down of three-phase asynchronous motors. Soft starting, reduction of current peaks, prevention of supply voltage fluctuations during startup, reduction of load on the power supply network, reduction of mechanical load in the drive, considerable saving of space and wiring compared to star-delta (wye-delta) starters and frequency converters, maintenance-free switching and extremely easy handling. The integrated bypass allows a very compact construction and ensures low heat dissipation in the control cabinet. Intelligent monitoring functions protect the soft starter against overheating and the motor against overload. In addition, you can limit the current during startup to a settable maximum value. Thanks to 3-phase control, particularly suitable for high motor outputs and inside-delta circuits. The innovative torque control ensures ideal motor startup. Integral display for fast commissioning and status displays. Provision of energy data via PROFINET, for example. Worldwide approvals (e.g. IEC and UL/CSA). The 3RW soft starters are available for supply systems up to 690 V in a wide performance range with different control supply voltages and all with both screw and spring-loaded terminals. For the 3RW30/40 there are additional versions with 24 V control supply voltage. Some of the 3RW40 up to size S3, and all 3RW44 units also offer thermistor motor protection. Optional communication modules allow connection via PROFIBUS and PROFINET. A display and operator module is also available for installation in the control cabinet door. Simple, efficient and always up to date – SIRIUS modular system.

Specification

  • Rated power three-phase motor, inside delta, at 400 V : 160000 kW
  • Torque control : Yes
  • With display : Yes
  • Integrated motor overload protection : Yes
  • Internal bypass : Yes
  • Rated control supply voltage Us at AC 60HZ : 230 – 230 V
  • Rated control supply voltage Us at DC : – V
  • Rated control supply voltage Us at AC 50HZ : 230 – 230 V
  • Rated operating voltage Ue : 400 – 600 V
  • Voltage type for actuating : AC
  • Rated power three-phase motor, inside delta, at 230 V : – kW
  • Rated power three-phase motor, inline, at 400 V : 90000 kW
  • Rated operation current Ie at 40 °C Tu : 162 A
  • Function : Single direction
  • Rated surrounding temperature without derating : 40 °C
  • Rated power three-phase motor, inline, at 230 V : – kW
  • Degree of protection (IP) : IP00