SIRIUS Motor Starter M200D AS-Interface Communication: AS-Interface

£762.62 inc VAT £635.52 ex VAT

SKU: 1050439036 Category: Tags: , ,

Description

Detail

SIRIUS motor starter M200D AS-i Communication: AS-Interface Reversing starter Basic Mechanical switching AC-3, 0.75KW / 400 V 0.15 A…2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC without brake contact 2DI AS-i + 2DI / 1DO on device Han Q4/2 – Han Q8/0 Motor starters SIRIUS M200D for starting, monitoring and protecting motors and loads for use in the field, for example in conveyor systems. The rugged motor starters with a high degree of protection for AS-Interface are easy to configure and, thanks to the modular starter concept and pre-assembled cables, they can be installed quickly without any errors and replaced equally quickly during servicing. The integration of associated sensors is supported. The use of the devices increases the availability of the plant thanks to the comprehensive diagnostics concept and sophisticated plant monitoring. The Motor Starter ES software is available for configuration, commissioning, operation and diagnostics. The motor starters are approved for worldwide use (e.g. IEC and UL/CSA) and are IE3/IE4-ready. Available as direct-on-line or reversing starter with various motor current ranges, optionally electromechanical or electronic switching, optionally with brake control or local operator panel. An extensive range of accessories, such as pre-assembled cables, suitable for all M200D motor starters, is available. SIRIUS M200D – The rugged motor starter for distributed drive solutions.

Specification

  • Supporting protocol for SERCOS : No
  • Supporting protocol for LON : No
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for ASI : Yes
  • Supporting protocol for PROFIBUS : No
  • Supporting protocol for CAN : No
  • Supporting protocol for INTERBUS : No
  • Supporting protocol for MODBUS : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for SUCONET : No
  • Supporting protocol for other bus systems : No
  • External reset possible : Yes
  • Rail mounting possible : No
  • Rated control supply voltage Us at DC : 20.4 – 28.8 V
  • Supporting protocol for INTERBUS-Safety : No
  • With short-circuit release : Yes
  • With fuse : No
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for PROFIsafe : No
  • Supporting protocol for SafetyBUS p : No
  • Temperature compensated overload protection : Yes
  • With transformer : No
  • Rated conditional short-circuit current, type 1, 480 Y/277 V : 50000 A
  • Kind of motor starter : Reversing starter
  • Voltage type for actuating : DC
  • Degree of protection (NEMA) : 12
  • Release class : CLASS 10
  • Degree of protection (IP) : IP65
  • Number of command positions : 2
  • Number of auxiliary contacts as normally open contact : 0
  • Number of auxiliary contacts as normally closed contact : 0
  • Number of indicator lights : 12
  • Ambient temperature, upper operating limit : 40 °C
  • Rated conditional short-circuit current, type 2, 400 V : 50000 A
  • Rated conditional short-circuit current, type 2, 230 V : 50000 A
  • Rated operation current at AC-3, 400 V : 2 A
  • Coordination class according to IEC 60947-4-3 : Class 2
  • Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
  • Rated operation current Ie : 2 A
  • Rated operation power at AC-3, 230 V, 3-phase : 0.37 kW
  • Rated power, 460 V, 60 Hz, 3-phase : 0.75 kW
  • Rated operation power at AC-3, 400 V : 0.75 kW
  • Rated power, 575 V, 60 Hz, 3-phase : – kW
  • Width : 294 mm
  • Height : 215 mm
  • Depth : 159 mm
  • Overload release current setting : 0.15 – 2 A
  • Rated control supply voltage Us at AC 50HZ : – V
  • Rated control supply voltage Us at AC 60HZ : – V
  • Suitable for emergency stop : No