Description
Detail
SIRIUS MCU motor starter Enclosure degree of protection IP55 plastic Communication without electromechanically switching Short-circuit protection with circuit breaker DOL starter Brake without Performance class 6.30 A Motor circuit breaker with bi-metal thermal Manual operation without Connection power M screw connection Standard product
Specification
External reset possible : No
Temperature compensated overload protection : Yes
With transformer : No
Suitable for emergency stop : No
Supporting protocol for LON : No
Supporting protocol for TCP/IP : No
Supporting protocol for ASI : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for MODBUS : No
Supporting protocol for Data-Highway : No
Supporting protocol for DeviceNet : No
Supporting protocol for SUCONET : No
Supporting protocol for other bus systems : No
Rated control supply voltage Us at DC : 20.4 – 26.4 V
Rail mounting possible : No
Supporting protocol for SERCOS : No
Supporting protocol for INTERBUS-Safety : No
With short-circuit release : Yes
With fuse : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Rated operation current at AC-3, 400 V : 6.3 A
Type of electrical connection of main circuit : Screw connection
Type of electrical connection for auxiliary- and control current circuit : Screw connection
Coordination class according to IEC 60947-4-3 : Class 1
Kind of motor starter : Direct starter
Release class : CLASS 10
Degree of protection (IP) : IP55
Number of command positions : 0
Number of auxiliary contacts as normally open contact : 2
Number of auxiliary contacts as normally closed contact : 1
Ambient temperature, upper operating limit : 40 °C
Number of indicator lights : 0
Rated conditional short-circuit current, type 2, 400 V : 150000 A
Rated conditional short-circuit current, type 2, 230 V : 150000 A
Voltage type for actuating : DC
Rated conditional short-circuit current, type 1, 480 Y/277 V : 150000 A
Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
Rated operation power at AC-3, 230 V, 3-phase : 1.5 kW
Rated operation current Ie : 6.3 A
Rated power, 575 V, 60 Hz, 3-phase : – kW
Rated power, 460 V, 60 Hz, 3-phase : – kW
Rated operation power at AC-3, 400 V : 2.2 kW
Width : 182 mm
Height : 220 mm
Depth : 145 mm
Overload release current setting : 4.5 – 6.3 A
Rated control supply voltage Us at AC 50HZ : – V
Rated control supply voltage Us at AC 60HZ : – V