SIRIUS MCU Motor Starter Enclosure Degree Of Protection IP55 Plastic Communication Without Electromechanically Switching Short-Circuit Protection With

£402.94 inc VAT £335.78 ex VAT

SKU: 1050439408 Category: Tags: ,

Description

Detail

SIRIUS MCU motor starter Enclosure degree of protection IP55 plastic Communication without electromechanically switching Short-circuit protection with circuit breaker DOL starter Brake without Performance class 1.00 A Motor circuit breaker with bi-metal thermal Manual operation without Connection power M screw connection Standard product

  • · SIRIUS MCU motor starter Enclosure degree of protection IP55 plastic Communication without electromechanically switching Short-circuit protection with

Specification

  • Suitable for emergency stop : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for INTERBUS-Safety : No
  • With short-circuit release : Yes
  • With fuse : No
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for PROFIsafe : No
  • Supporting protocol for SafetyBUS p : No
  • Temperature compensated overload protection : Yes
  • With transformer : No
  • Rated control supply voltage Us at AC 50HZ : – V
  • Supporting protocol for LON : No
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for ASI : No
  • Supporting protocol for PROFIBUS : No
  • Supporting protocol for CAN : No
  • Supporting protocol for INTERBUS : No
  • Supporting protocol for MODBUS : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for SUCONET : No
  • Supporting protocol for other bus systems : No
  • External reset possible : No
  • Rail mounting possible : No
  • Rated conditional short-circuit current, type 1, 480 Y/277 V : 150000 A
  • Type of electrical connection for auxiliary- and control current circuit : Screw connection
  • Type of electrical connection of main circuit : Screw connection
  • Coordination class according to IEC 60947-4-3 : Class 1
  • Kind of motor starter : Direct starter
  • Degree of protection (IP) : IP55
  • Release class : CLASS 10
  • Number of command positions : 0
  • Number of auxiliary contacts as normally closed contact : 1
  • Number of auxiliary contacts as normally open contact : 2
  • Number of indicator lights : 0
  • Rated conditional short-circuit current, type 2, 400 V : 150000 A
  • Rated conditional short-circuit current, type 2, 230 V : 150000 A
  • Rated operation current at AC-3, 400 V : 1 A
  • Voltage type for actuating : DC
  • Ambient temperature, upper operating limit : 40 °C
  • Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
  • Rated operation current Ie : 1 A
  • Rated operation power at AC-3, 230 V, 3-phase : 0.18 kW
  • Rated power, 460 V, 60 Hz, 3-phase : – kW
  • Rated power, 575 V, 60 Hz, 3-phase : – kW
  • Rated operation power at AC-3, 400 V : 0.3 kW
  • Width : 182 mm
  • Height : 220 mm
  • Depth : 145 mm
  • Rated control supply voltage Us at AC 60HZ : – V
  • Rated control supply voltage Us at DC : 20.4 – 26.4 V
  • Overload release current setting : 0.7 – 1 A