Description
Detail
SIRIUS MCU motor starter Enclosure degree of protection IP55 plastic Communication without electromechanically switching short-circuit protection with circuit breaker Reversing starter Brake without performance class 3.2 A Motor circuit breaker with bi-metal thermal Manual operation latching Connection power M screw connection Electrical wholesale version
Specification
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for LON : No
Supporting protocol for TCP/IP : No
Supporting protocol for ASI : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for MODBUS : No
Supporting protocol for Data-Highway : No
Supporting protocol for DeviceNet : No
Supporting protocol for SUCONET : No
Supporting protocol for other bus systems : No
External reset possible : No
Rail mounting possible : No
Supporting protocol for SERCOS : No
Rated control supply voltage Us at DC : – V
With short-circuit release : Yes
With fuse : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Temperature compensated overload protection : Yes
Suitable for emergency stop : No
With transformer : No
Rated operation current at AC-3, 400 V : 3.2 A
Kind of motor starter : Reversing starter
Type of electrical connection of main circuit : Screw connection
Coordination class according to IEC 60947-4-3 : Class 1
Voltage type for actuating : AC
Release class : CLASS 10
Degree of protection (IP) : IP55
Number of command positions : 2
Number of auxiliary contacts as normally closed contact : 3
Number of auxiliary contacts as normally open contact : 1
Number of indicator lights : 0
Ambient temperature, upper operating limit : 40 °C
Rated conditional short-circuit current, type 2, 400 V : 150000 A
Rated conditional short-circuit current, type 2, 230 V : 150000 A
Type of electrical connection for auxiliary- and control current circuit : Spring clamp connection
Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
Rated conditional short-circuit current, type 1, 480 Y/277 V : 150000 A
Rated operation current Ie : 3.2 A
Rated operation power at AC-3, 230 V, 3-phase : 0.55 kW
Rated power, 460 V, 60 Hz, 3-phase : – kW
Rated power, 575 V, 60 Hz, 3-phase : – kW
Rated operation power at AC-3, 400 V : 1.1 kW
Height : 220 mm
Width : 182 mm
Depth : 145 mm
Overload release current setting : 2.2 – 3.2 A
Rated control supply voltage Us at AC 50HZ : 184 – 253.0 V
Rated control supply voltage Us at AC 60HZ : 196 – 253.0 V