SIRIUS, Central Unit 3RK3 Basic For Modular Safety System 3RK3 4/8 F-DI

£1,130.24 inc VAT £941.87 ex VAT

SKU: 1050439357 Category: Tag:

Description

Detail

SIRIUS, central unit 3RK3 Basic for modular Safety system 3RK3 4/8 F-DI,1F-RO,1 F-DO,24 V DC parameterizable using software Safety ES 45 mm overall width Spring-type terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) Central unit SIRIUS 3RK3 for complex safety applications.

  • · SIRIUS, central unit 3RK3 basic for Modular Safety System 3RK3 4/8 F-DI

Specification

  • With approval for TÜV : Yes
  • Rated control supply voltage Us at AC 50HZ : – – – V
  • Rated control supply voltage Us at AC 60HZ : – – – V
  • With approval according to UL : Yes
  • Rated control supply voltage Us at DC : 24 – 24 V
  • With detachable clamps : Yes
  • With start input : No
  • With feedback circuit : No
  • Rail mounting possible : No
  • With muting function : No
  • Release-delay : – s
  • With approval for BG BIA : No
  • Suitable for monitoring of magnetic switches : No
  • Suitable for monitoring of proximity switches : Yes
  • Suitable for monitoring of emergency-stop circuits : Yes
  • Suitable for monitoring of optoelectronic protection equipment : Yes
  • Suitable for monitoring of position switches : Yes
  • Suitable for monitoring of tactile sensors : No
  • Suitable for monitoring of valves : Yes
  • Number of outputs, safety related, undelayed, semiconductors : 1
  • Type of electric connection : Spring clamp connection
  • Voltage type for actuating : DC
  • Category according to EN 954-1 : 4
  • SIL according to IEC 61508 : 3
  • Model : Basic device
  • Performance level acc. EN ISO 13849-1 : Level e
  • Number of outputs, safety related, undelayed, with contact : 0
  • Number of outputs, safety related, delayed, with contact : –
  • Stop category acc. IEC 60204 : 0 + 1
  • Number of outputs, signalling function, undelayed, with contact : –
  • Number of outputs, signalling function, delayed, with contact : –
  • Number of outputs, signalling function, undelayed, semiconductors : –
  • Number of outputs, safety related, delayed, semiconductors : –
  • Number of outputs, signalling function, delayed, semiconductors : –
  • Height : 113 mm
  • Width : 45 mm
  • Depth : 124 mm