Schneider XU9M18MB230 P/E Sensor 2m
£182.04 inc VAT £151.70 ex VAT
Description
Detail
M18 PHOTO AC/DC POL
- · This photo-electric sensor is part of the XU Application range. It is recommended for building and tertiary sectors.
- · This sensor has a design 18 format body, pre-cabled.
- · This sensor is pre-cabled, 2m, with the line of sight along case axis.
- · 2-wire AC or DC supply, NC function. Solid-state output with adjsutable sensitivity.
- · 2m sensing distance. Polarized reflex system.
Specification
Analogue output -10 V … +10 V : No
Length of sensor : 82 mm
Max. switching distance : 3000 mm
Rated switching distance : 2000 mm
Ambient temperature : -25 – 55 °C
Rated control supply voltage Us at AC 50HZ : 24 – 240 V
Rated control supply voltage Us at AC 60HZ : 24 – 240 V
Rated control supply voltage Us at DC : 24 – 240 V
Suitable for safety functions : No
With time function : No
With monitoring function downstream switching devices : No
With restart blockage : No
Pre failure notice : No
Analogue output 0 V … 10 V : No
Analogue output 0 mA … 20 mA : No
Analogue output 4 mA … 20 mA : No
Height of sensor : 0 mm
With communication interface analogue : No
With communication interface AS-Interface : No
With communication interface CANOpen : No
With communication interface DeviceNet : No
With communication interface Ethernet : No
With communication interface INTERBUS : No
With communication interface PROFIBUS : No
With communication interface RS-232 : No
With communication interface RS-422 : No
With communication interface RS-485 : No
With communication interface SSD : No
With communication interface SSI : No
Reflector included : No
With other analogue output : No
Max. output current : 200 mA
Explosion safety category for dust : None
Material of optical surface : Plastic
Laser protection class : None
Explosion safety category for gas : None
Voltage type : AC/DC
Type of safety acc. IEC 61496-1 : 1
Material housing : Metal
Degree of protection (IP) : IP67
Sensing mode : Dark switching
Type of light : Polarized red light
Setting procedure : Manual adjustment
Type of switch function : Breaker contact (NC)
Operation agent-safety class : Safety class 0
Type of switching output : Two-wire
Construction type housing : Cylinder, screw-thread
Type of electric connection : Cable
Switching frequency : 25 Hz
Number of semiconductor outputs with signalling function : 1
Number of protected semiconductor outputs : 0
Number of contact energized outputs with signalling function : 0
Number of protected contact energized outputs : 0
Light dot : 0 mm²
Max. output current at protected output : 200 mA
Min. reflector distance : 1000 mm
Time of reaction : 20 ms
Transmission range of the safety field : 0 m
Switching voltage of OSSD at state “high” : 0 V
Wavelength of the sensor : 0 nm
Width sensor : 0 mm
Diameter sensor : 18 mm