Description
Detail
Reversing Starter TeSys H Safe-Torque-Off 0,75kW-400V control 110-230VAC. range: TeSys – product name: TeSys H – device short name: LZ8H – product or component type: reversing ultra-compact starter – poles description: 3P – [Ie] rated operational current: 2.4 A at 500 V AC-51, 2.4 A at 500 V AC-51 mounting side by side, 2.4 A at 500 V AC-53A, 2.4 A at 500 V AC-53A mounting side by side – motor power kW: 0.37 kW at 220 V AC with power factor : 0.65, 0.37 kW at 230 V AC with power factor : 0.65, 0.75 kW at 380 V AC with power factor : 0.65, 0.75 kW at 400 V AC with power factor : 0.65, 0.75 kW at 415 V AC with power factor : 0.65, 0.75 kW at 440 V AC with power factor : 0.65, 1.1 kW at 500 V AC with power factor : 0.65 – motor power hp: 0.5 hp at 200 V AC, 0.5 hp at 230 V AC, 1 hp at 460 V AC – safety level: PL = e conforming to ISO 13849-1 stop function, SIL 2 conforming to IEC 61508-1 motor protection, SIL 3 conforming to IEC 61508-1 stop function – safety reliability data: MTTFd = 273 years motor protection, MTTFd = 289 years stop function, PFHd = 6.82E-9 1/h stop function, SFF = 99 % motor protection, SFF = 99 % stop function.
Specification
Supporting protocol for EtherNet/IP : No
Supporting protocol for INTERBUS : No
Supporting protocol for CAN : No
Supporting protocol for Data-Highway : No
Supporting protocol for MODBUS : No
Suitable for emergency stop : Yes
Supporting protocol for LON : No
Supporting protocol for SERCOS : No
External reset possible : Yes
Supporting protocol for DeviceNet : No
Supporting protocol for SUCONET : No
With short-circuit release : No
Supporting protocol for other bus systems : No
Supporting protocol for PROFIBUS : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for PROFINET CBA : No
Rail mounting possible : Yes
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for PROFINET IO : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for PROFIsafe : No
With fuse : No
Temperature compensated overload protection : Yes
Number of indicator lights : 4
Release class : CLASS 10
Degree of protection (IP) : IP20
Type of electrical connection for auxiliary- and control current circuit : Screw connection
Kind of motor starter : Reversing starter
Voltage type for actuating : AC
Rated operation power at AC-3, 230 V, 3-phase : 0.37 kW
Rated operation power at AC-3, 400 V : 0.75 kW
Rated power, 460 V, 60 Hz, 3-phase : 0.75 kW
Depth : 113.4 mm
Height : 106.5 mm
Width : 22.6 mm
Rated operation current Ie : 2.4 A
Type of electrical connection of main circuit : Screw connection
Ambient temperature, upper operating limit : 70 °C
Number of auxiliary contacts as normally open contact : 0
Number of auxiliary contacts as normally closed contact : 0
Rated operation current at AC-3, 400 V : 2.4 A
Number of command positions : 0
Rated control supply voltage Us at AC 50HZ : 110 – 230 V
Overload release current setting : 0.18 – 2.4 A
Rated control supply voltage Us at AC 60HZ : 110 – 230 V
With transformer : No
Supporting protocol for TCP/IP : No
Supporting protocol for ASI : No