Reversing Starter, 0.4-2 A, 24 V DC, Screw Terminal

£291.10 inc VAT £242.58 ex VAT

SKU: 1050439445 Category: Tags: ,

Description

Detail

Reversing starter, 3RM1, 500 V, 0.09 – 0.75 kW, 0.4 – 2 A, 24 V DC, screw terminals Reversing starter SIRIUS 3RM1 for functional switching of three-phase motors. Narrow design, multifunctional, with electronic overload protection, durable and energy-efficient hybrid switching technology, small number of different devices due to wide setting ranges, easy installation thanks to low wiring requirements, fast error diagnostics due to LED display, innovative enclosure concept, e.g. with labeled cover caps and removable terminals. Available as direct or reversing starter, optionally with ATEX certification and safety-related shutdown, with various motor current ranges, supply voltage types and connection technologies. An extensive range of accessories, such as device connector, fuse module, infeed system or sealable covers, completes the system. Getting started in minimum space – SIRIUS 3RM1 motor starters.

Specification

  • Rail mounting possible : Yes
  • Supporting protocol for ASI : No
  • Supporting protocol for PROFIBUS : No
  • Rated control supply voltage Us at DC : 24 – 24 V
  • Supporting protocol for CAN : No
  • Supporting protocol for INTERBUS : No
  • Supporting protocol for MODBUS : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for SUCONET : No
  • With transformer : No
  • Suitable for emergency stop : No
  • Supporting protocol for other bus systems : No
  • External reset possible : Yes
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for INTERBUS-Safety : No
  • With short-circuit release : No
  • With fuse : No
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for SafetyBUS p : No
  • Temperature compensated overload protection : No
  • Supporting protocol for PROFIsafe : No
  • Rated operation power at AC-3, 230 V, 3-phase : 0.37 kW
  • Type of electrical connection of main circuit : Screw connection
  • Type of electrical connection for auxiliary- and control current circuit : Screw connection
  • Number of auxiliary contacts as normally open contact : 1
  • Degree of protection (IP) : IP20
  • Number of command positions : 0
  • Number of auxiliary contacts as normally closed contact : 1
  • Release class : CLASS 10 A
  • Ambient temperature, upper operating limit : 60 °C
  • Rated operation current at AC-3, 400 V : 2 A
  • Rated conditional short-circuit current, type 2, 230 V : – A
  • Rated conditional short-circuit current, type 2, 400 V : – A
  • Rated conditional short-circuit current, type 1, 480 Y/277 V : – A
  • Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
  • Voltage type for actuating : DC
  • Number of indicator lights : 4
  • Rated power, 575 V, 60 Hz, 3-phase : – kW
  • Rated power, 460 V, 60 Hz, 3-phase : 0.55162 kW
  • Rated operation current Ie : 2 A
  • Rated operation power at AC-3, 400 V : 0.75 kW
  • Height : 100 mm
  • Depth : 141.6 mm
  • Width : 22.5 mm
  • Overload release current setting : 2 – 2 A
  • Rated control supply voltage Us at AC 50HZ : – V
  • Rated control supply voltage Us at AC 60HZ : – V
  • Supporting protocol for LON : No