RCBO Compact 1P+N 6 Ka Type Ac 30 Ma C2

£168.53 inc VAT £140.44 ex VAT

Description

Detail

RCBO compact 1P+N 6 kA type AC 30 mA C2 The RCD is the residual current device for touch protection The patented residual current protective devices from Siemens are an important component of the SENTRON protective components for electrical installations because they prevent life-threatening electrical accidents by safely disconnecting hazardous residual currents through grounding. Electrically ignited fires can be prevented as they occur. Whether by direct contact with energized operating parts or by indirect contact with equipment, protection is mainly achieved by a quick shutdown. The Siemens 5SV RCCBs are characterized primarily by: 1. Comprehensive protection from electric shock for personnel and property. 2. Whether sinusoidal residual alternating currents or smooth residual direct currents, Siemens provides the right type for all requirements and special versions. 3. Reliable safety during installation due to standard reach-around and touch protection. 4. Toolless removal from the standard mounting rail or from the busbar assembly simply by operating a manual slide. 5. The data matrix code on the front of the device provides quick and easy access to information on all aspects of RCCBs. 6. Be protected according to the standards: The RCCBs meet the provisions of DIN VDE. 7. Optimized technology for your safety – only from Siemens.

  • · RCBO compact 6kA Type AC 30mA C2

Specification

  • Rated short-circuit breaking capacity Icn acc. EN 61009-1 : 6 kA
  • Anti-nuisance tripping version : Yes
  • Suitable for flush-mounted installation : Yes
  • With interlocking device : Yes
  • Concurrently switching N-neutral : Yes
  • Connectable conductor cross section solid-core : 0.75 – 16.0 mm²
  • Connectable conductor cross section multi-wired : 0.75 – 16.0 mm²
  • Rated insulation voltage Ui : 253 V
  • Rated voltage : 230 V
  • Rated impulse withstand voltage Uimp : 4 kV
  • Built-in depth : 70 mm
  • Rated short-circuit breaking capacity acc. EN 61009 : 6 kA
  • Rated short-circuit breaking capacity IEC 60947-2 : 10 kA
  • Degree of protection (IP) : IP20
  • Rated fault current : 0.03 A
  • Rated current : 2 A
  • Number of protected poles : 1
  • Width in number of modular spacings : 1
  • Number of poles (total) : 2
  • Pollution degree : 2
  • Over voltage category : 3
  • Current limiting class : 3
  • Release characteristic : C
  • Voltage type : AC
  • Leakage current type : AC
  • Disconnection characteristic : Undelayed