Pressure switch XMLA 500 bar, fixed scale 1 threshold, 1 C/O

£410.77 inc VAT £342.31 ex VAT

SKU: 2500254160 Category: Tags: , ,

Description

Detail

Pressure switch XMLA 500 bar, fixed scale 1 threshold, 1 C/O. range of product: OsiSense XM – product or component type: electromechanical pressure sensor – device short name: XMLA – pressure sensor size: 500 bar – product specific application: – – electrical circuit type: control circuit – scale type: fixed differential – local display: with – adjustable range of switching point on rising pressure: 30…500 bar – adjustable range of switching point on falling pressure: 10…455 bar – maximum permissible accidental pressure: 1125 bar – destruction pressure: 2250 bar – pressure actuator: piston – materials in contact with fluid: brass, FPM, FKM, PTFE, stainless steel, steel – enclosure material: zinc alloy – [In] rated current: 0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1, 1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5-1, 3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1.

  • · This XMLA electromechanical pressure switch has a fixed differential for detection of a single threshold and a zinc alloy body with a range scale window.
  • · This pressure switch is designed for detection of a single pressure threshold in hydraulic oils up to 160°C.
  • · It is fixed directly on tubage.
  • · It provides zinc alloy enclosure for robust performance.
  • · 6 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits.

Specification

  • Initial setting : 30000 – 500000 hPa
  • Suitable as guard : Yes
  • Electronic version : No
  • Suitable as limiter : Yes
  • With hand operation : No
  • Suitable as 2-point controller : No
  • Explosion-proof : No
  • With manual on/off switch : No
  • Medium temperature : 0 – 160 °C
  • Rated voltage Ue at DC : 250 – 250 V
  • Switch off pressure : 10 – 455 bar
  • Adjustable current range : 0 – 0 A
  • Rated voltage Ue at AC 60 Hz : 120 – 240 V
  • Engaging pressure : 30 – 500 bar
  • Rated voltage Ue at AC 50 Hz : 120 – 240 V
  • End setting : 10000 – 455000 hPa
  • Degree of protection (IP) : IP65
  • Rated operation current Ie at AC-1, 400 V : 0 A
  • Rated operation current Ie at AC-3, 400 V : 0 A
  • Switching capacity at AC-3, 240 V : 0 kA
  • Rated operation power at AC-3, 400 V : 0 kW
  • Initial value measuring range pressure : 0 Pa
  • Number of auxiliary contacts as normally closed contact : 0
  • Max. operation pressure : 625000 hPa
  • End value measuring range pressure : 0 Pa
  • Number of normally closed contacts as main contact : 0
  • Number of auxiliary contacts as normally open contact : 0
  • Pressure-switching differential : 45 bar
  • Number of auxiliary contacts as change-over contact : 1
  • Max. test pressure : 1125 bar
  • Bursting pressure : 2250 bar
  • Number of main contacts as normally open contact : 0