Pressure sensors XMLR -1 bar, G 1/4, 24VDC, 0..10 V, M12

£643.68 inc VAT £536.40 ex VAT

SKU: 2500894561 Category: Tags: , ,

Description

Detail

Pressure sensors XMLR -1 bar, G 1/4, 24VDC, 0..10 V, M12. range of product: OsiSense XM – product or component type: electronic pressure sensors – pressure switch type of operation: pressure transmitter – device short name: XMLR – pressure sensor size: -1 bar, -14.5 psi – maximum permissible accidental pressure: 3 bar, 300 kPa, 43 psi – destruction pressure: 3 bar, 300 kPa, 43 psi – controlled fluid: air (-20…80 °C), fresh water (0…80 °C), hydraulic oil (-20…80 °C), refrigeration fluid (-20…80 °C).

  • · This XMLR electronic pressure sensor has a 4 digit 7-segment display.
  • · This electronic pressure transmitter sensor with digital display is designed for accurate pressure measurement and display.
  • · It is fixed directly on tubage.
  • · It provides high corrosion resistance AISI 316L stainless steel and fluorocarbon resin pressure chamber for maximum longevity.
  • · 10 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits.

Specification

  • Rated voltage Ue at AC 60 Hz : 0 – 0 V
  • Suitable as limiter : No
  • Suitable as guard : Yes
  • Electronic version : Yes
  • With hand operation : No
  • Explosion-proof : No
  • Suitable as 2-point controller : No
  • With manual on/off switch : No
  • Adjustable current range : 0 – 0 A
  • Medium temperature : -20 – 80 °C
  • Switch off pressure : -1 – 0 bar
  • End setting : 0 – 0 hPa
  • Rated voltage Ue at DC : 24 – 24 V
  • Engaging pressure : -1 – 0 bar
  • Initial setting : -1000 – 0 hPa
  • Rated voltage Ue at AC 50 Hz : 0 – 0 V
  • Degree of protection (IP) : IP65/IP67
  • Rated operation current Ie at AC-1, 400 V : 0 A
  • Pressure-switching differential : 0 bar
  • Number of auxiliary contacts as change-over contact : 0
  • Switching capacity at AC-3, 240 V : 0 kA
  • End value measuring range pressure : -100000 Pa
  • Max. test pressure : 3 bar
  • Initial value measuring range pressure : 0 Pa
  • Bursting pressure : 3 bar
  • Rated operation current Ie at AC-3, 400 V : 0 A
  • Max. operation pressure : -1000 hPa
  • Number of main contacts as normally open contact : 0
  • Number of normally closed contacts as main contact : 0
  • Rated operation power at AC-3, 400 V : 0 kW
  • Number of auxiliary contacts as normally open contact : 0
  • Number of auxiliary contacts as normally closed contact : 0