Power Base Tesys U 32A 24V DC Screw Clamps Control

£294.40 inc VAT £245.33 ex VAT

Description

Detail

Power base, TeSys U, 32A, 24 V DC screw clamps control. range: TeSys – product name: TeSys U – device short name: LU2B – product or component type: reversing power base – device application: motor – poles description: 3P – suitability for isolation: yes – [Ith] conventional free air thermal current: 32 A – utilisation category: AC-41, AC-43, AC-44.

  • · Height: 224mm
  • · Range: Tesys U
  • · Width: 45mm
  • · Weight: 1.27kg
  • · Depth: 126mm

Specification

  • With short-circuit release : Yes
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for ASI : No
  • Supporting protocol for MODBUS : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for DeviceNet : No
  • External reset possible : No
  • Supporting protocol for INTERBUS : No
  • Supporting protocol for LON : No
  • Supporting protocol for PROFIBUS : No
  • Suitable for emergency stop : No
  • Supporting protocol for CAN : No
  • Supporting protocol for SUCONET : No
  • Supporting protocol for other bus systems : No
  • With transformer : No
  • With fuse : No
  • Supporting protocol for SERCOS : No
  • Rail mounting possible : Yes
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for INTERBUS-Safety : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for SafetyBUS p : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for PROFIsafe : No
  • Temperature compensated overload protection : Yes
  • Number of command positions : 3
  • Voltage type for actuating : DC
  • Degree of protection (IP) : IP20
  • Kind of motor starter : Reversing starter
  • Type of electrical connection for auxiliary- and control current circuit : Screw connection
  • Number of auxiliary contacts as normally open contact : 1
  • Rated conditional short-circuit current, type 1, 600 Y/347 V : 0 A
  • Number of auxiliary contacts as normally closed contact : 1
  • Depth : 126 mm
  • Rated power, 460 V, 60 Hz, 3-phase : 0 kW
  • Rated conditional short-circuit current, type 1, 480 Y/277 V : 0 A
  • Rated power, 575 V, 60 Hz, 3-phase : 0 kW
  • Rated operation power at AC-3, 400 V : 15 kW
  • Height : 224 mm
  • Type of electrical connection of main circuit : Screw connection
  • Rated operation current Ie : 32 A
  • Rated operation power at AC-3, 230 V, 3-phase : 0 kW
  • Width : 45 mm
  • Rated operation current at AC-3, 400 V : 32 A
  • Ambient temperature, upper operating limit : 70 °C
  • Rated conditional short-circuit current, type 2, 400 V : 50 A
  • Rated conditional short-circuit current, type 2, 230 V : 50 A
  • Number of indicator lights : 0
  • Rated control supply voltage Us at AC 50HZ : 0 – 0 V
  • Rated control supply voltage Us at AC 60HZ : 0 – 0 V
  • Overload release current setting : 0 – 0 A
  • Rated control supply voltage Us at DC : 24 – 24 V