Description
Detail
Photo-electric sensor, XU2, thru beam, Sn 15m, 24..240VAC/DC, 1/2″. range of product: OsiSense XU – series name: general purpose single mode – electronic sensor type: photo-electric sensor – sensor name: XU2 – detection system: thru beam – material: metal – line of sight type: axial – type of output signal: discrete – wiring technique: 2-wire – product specific application: -.
Specification
Rated control supply voltage Us at AC 60HZ : 24 – 240 V
Analogue output 4 mA … 20 mA : No
Analogue output 0 V … 10 V : No
Pre failure notice : No
With restart blockage : No
With monitoring function downstream switching devices : No
With time function : No
Suitable for safety functions : No
Ambient temperature : -25 – 55 °C
Reflector included : No
Rated control supply voltage Us at DC : 24 – 240 V
Rated control supply voltage Us at AC 50HZ : 24 – 240 V
Min. reflector distance : 0 mm
Light dot : 0 mm²
Number of protected contact energized outputs : 0
AWG-number : 0
Time of reaction : 20 ms
Max. output current at protected output : 0 mA
Analogue output 0 mA … 20 mA : No
With other analogue output : No
Analogue output -10 V … +10 V : No
With communication interface Ethernet : No
With communication interface analogue : No
With communication interface AS-Interface : No
With communication interface DeviceNet : No
With communication interface INTERBUS : No
With communication interface RS-232 : No
With communication interface PROFIBUS : No
With communication interface RS-485 : No
With communication interface RS-422 : No
With communication interface SSD : No
With communication interface CANOpen : No
With communication interface SSI : No
Sensing mode : Dark switching
Material housing : Metal
Voltage type : AC/DC
Laser protection class : None
Setting procedure : Manual adjustment
Explosion safety category for gas : None
Type of light : Infrared light
Explosion safety category for dust : None
Type of safety acc. IEC 61496-1 : 1
Type of switch function : Normally open contact (NO)
Type of switching output : Two-wire
Operation agent-safety class : Safety class 0
Degree of protection (IP) : IP67
Construction type housing : Cylinder, screw-thread
Material of optical surface : Plastic
Scope of delivery of the one-way system : Transmitter and receiver
Type of electric connection : Connector 1/2 inch
Switching frequency : 25 Hz
Rated switching distance : 15000 mm
Diameter sensor : 18 mm
Number of semiconductor outputs with signalling function : 1
Length of sensor : 95 mm
Width sensor : 0 mm
Transmission range of the safety field : 0 m
Switching voltage of OSSD at state “high” : 0 V
Opening angle : 0 °
Wavelength of the sensor : 0 nm
Max. switching distance : 20000 mm
Height of sensor : 0 mm
Max. output current : 200 mA
Number of protected semiconductor outputs : 0
Number of contact energized outputs with signalling function : 0