Circuit breaker 10kA, 2-pole, C, 5A according to UL 489-480Y/277V The miniature circuit breaker is the fuse for short-circuit protection. The miniature circuit breakers from Siemens, as an important component of the SENTRON protective components for electronic installations, provide effective protection for personnel and plants by reliably shutting down in the event of an overload or short-circuit. User-friendly mounting and connection technology, standardized additional components and an integrated design – these are the characteristics of the device family. Whether for infrastructure or for industrial requirements, Siemens provides miniature circuit breakers for all applications and every application area. The Siemens miniature circuit breakers are characterized primarily by: 1. Effective personnel, investment and plant protection against overload and short-circuits. 2. A wide variety of standardized accessories, easy to install and replaceable at any time. 3. Reliable safety during installation due to standard reach-around and touch protection. 4. Clearly visible switch position indicator. 5. The data matrix code on the front of the device provides quick and easy access to information on all aspects of miniature circuit breakers. 6. Protection as per the standards with worldwide approvals.

Specification

  • Rated short-circuit breaking capacity Icu IEC 60947-2 at 230 V : 15 kA
  • Additional equipment possible : Yes
  • Suitable for flush-mounted installation : No
  • Concurrently switching N-neutral : No
  • Ambient temperature during operating : -25 – 55 °C
  • Connectable conductor cross section multi-wired : – mm²
  • Connectable conductor cross section solid-core : – mm²
  • Frequency : 50 – 50 Hz
  • Rated insulation voltage Ui : 440 V
  • Rated voltage : 400 V
  • Built-in depth : 70 mm
  • Rated impulse withstand voltage Uimp : – kV
  • Rated short-circuit breaking capacity Icu IEC 60947-2 at 400 V : 15 kA
  • Degree of protection (IP) : IP20
  • Rated short-circuit breaking capacity Icn EN 60898 at 230 V : 10 kA
  • Rated short-circuit breaking capacity Icn EN 60898 at 400 V : 10 kA
  • Rated current : 5 A
  • Number of protected poles : –
  • Pollution degree : 3
  • Width in number of modular spacings : 2
  • Number of poles (total) : 2
  • Over voltage category : 3
  • Release characteristic : C
  • Current limiting class : –
  • Voltage type : AC/DC