Metal safety switch XCSLF, 2 NC+2 NO- slow break, 3 entries tapped M20

£272.52 inc VAT £227.10 ex VAT

Description

Detail

Metal safety switch XCSLF, 2 NC+2 NO- slow break, 3 entries tapped M20, 24V. range of product: Preventa Safety detection – product or component type: safety switch – component name: XCSLF – head type: key operated turret head – contacts type and composition: 1 NC + 1 NO – electromagnet interlocking: locking on de-energisation and unlocking on energisation of solenoid – cable outer diameter: 7…13 mm – electrical connection: spring terminal, 1 x 1.5 mm² flexible or solid cable, spring terminal, 2 x 0.5 mm² flexible cables with 13 mm bared ends – local signalling: 1 LED green (actuator inserted and locked), 1 LED orange (actuator withdrawn).

  • · This XCSLF Key Operated Safety Switch for guard doors with locking by solenoid has an adjustable turret head and a robust red coated slim Zamak body with 3 x M20 cable gland entries, allowing for flexible installation.
  • · It has 1 normally open and 1 normally closed break-before-make (slow break) main contacts actuated by key, contact states given when the key is inserted.
  • · And it has 1 normally open and 1 normally closed auxiliary contacts actuated by the solenoid, contact states given when the solenoid is not powered.

Specification

  • Length of sensor : 51 mm
  • With escape release : No
  • With status indication : Yes
  • Suitable for safety functions : Yes
  • Rated control supply voltage Us magnet drive at DC : 24 – 24 V
  • Rated control supply voltage Us magnet drive at AC 50 Hz : 24 – 24 V
  • Ambient temperature during operating : -25 – 60 °C
  • Rated control supply voltage Us magnet drive at AC 60 Hz : 24 – 24 V
  • Guard locking force : 20 N
  • Rated operation current Ie at DC-13, 230 V : 0 A
  • Rated operation current Ie at AC-15, 24 V : 0 A
  • Rated operation current Ie at AC-15, 125 V : 0 A
  • Number of safety auxiliary contacts : 0
  • Rated operation current Ie at DC-13, 125 V : 0 A
  • Number of contacts as change-over contact : 0
  • Locking mechanism : Operating current principle
  • Width sensor : 44 mm
  • Rated operation current Ie at DC-13, 24 V : 0.55 A
  • Height of sensor : 205 mm
  • Number of contacts as normally open contact : 1
  • Number of contacts as normally closed contact : 1
  • Rated operation current Ie at AC-15, 230 V : 0.75 A
  • Degree of protection (IP) : IP67
  • Type of switching contact : Slow-action switch
  • Type of interface : None
  • Type of electric connection : Cable entry metrical
  • Type of interface for safety communication : None
  • Explosion safety category for gas : None
  • Material housing : Metal