Description
Detail
Fail-safe reversing starter, 3RM1, 500 V, 0.09 – 0.75 kW, 0.4 – 2 A, 24 V DC, spring-type terminals Failsafe reversing starters SIRIUS 3RM1 for functional switching of three-phase motors. Narrow design, multifunctional, with electronic overload protection, durable and energy-efficient hybrid switching technology, small number of different devices due to wide setting ranges, easy installation thanks to low wiring requirements, fast error diagnostics due to LED display, innovative enclosure concept, e.g. with labeled cover caps and removable terminals. Available as direct or reversing starter, optionally with ATEX certification and safety-related shutdown, with various motor current ranges, supply voltage types and connection technologies. An extensive range of accessories, such as device connector, fuse module, infeed system or sealable covers, completes the system. Getting started in minimum space – SIRIUS 3RM1 motor starters.
- · REV. STARTER 0.4-2.0A, 24V SAFETY PUSH
Specification
Supporting protocol for PROFINET IO : No
With fuse : No
Supporting protocol for TCP/IP : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for ASI : No
Supporting protocol for MODBUS : No
Supporting protocol for DeviceNet : No
Supporting protocol for Data-Highway : No
Supporting protocol for SUCONET : No
Supporting protocol for LON : No
External reset possible : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for SERCOS : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for other bus systems : No
Rated power, 460 V, 60 Hz, 3-phase : 0.55162 kW
Release class : CLASS 10 A
Degree of protection (IP) : IP20
Number of auxiliary contacts as normally open contact : 1
Number of command positions : 0
Number of auxiliary contacts as normally closed contact : 1
Number of indicator lights : 4
Ambient temperature, upper operating limit : 60 °C
Rated operation current at AC-3, 400 V : 2 A
Rated operation current Ie : 2 A
Rated operation power at AC-3, 400 V : 0.75 kW
Rated operation power at AC-3, 230 V, 3-phase : 0.37 kW
Voltage type for actuating : DC
Height : 100 mm
Width : 22.5 mm
Depth : 141.6 mm
Rated control supply voltage Us at DC : 24 – 24 V
Overload release current setting : 2 – 2 A
With short-circuit release : No
Temperature compensated overload protection : No
Rail mounting possible : Yes
With transformer : No
Suitable for emergency stop : No