F-DS1E-X For ET 200S Failsafe Direct On-Line Starter, 2.4-16 A, Mech. Switching

£972.06 inc VAT £810.05 ex VAT

SKU: 1050438967 Category: Tags: , ,

Description

Detail

F-DS1E-X for ET 200S Fail-safe DOL starter Setting range 2.4…16 A Mechanical switching Electronic protection AC-3, up to 7.5 kW / 400 V expandable for brake control module for 2DI control module The ET 200S distributed I/O is superseded by the new ET 200SP system.

Specification

  • Rail mounting possible : No
  • Suitable for emergency stop : No
  • Supporting protocol for LON : No
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for ASI : No
  • Supporting protocol for PROFIBUS : No
  • Supporting protocol for CAN : No
  • Supporting protocol for INTERBUS : No
  • Supporting protocol for MODBUS : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for other bus systems : No
  • Supporting protocol for SUCONET : No
  • External reset possible : No
  • With transformer : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for INTERBUS-Safety : No
  • With short-circuit release : Yes
  • With fuse : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for PROFIsafe : No
  • Supporting protocol for SafetyBUS p : No
  • Temperature compensated overload protection : No
  • Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
  • Voltage type for actuating : DC
  • Degree of protection (IP) : IP20
  • Type of electrical connection of main circuit : Screw connection
  • Number of command positions : –
  • Kind of motor starter : Direct starter
  • Number of auxiliary contacts as normally open contact : –
  • Number of auxiliary contacts as normally closed contact : –
  • Number of indicator lights : –
  • Ambient temperature, upper operating limit : – °C
  • Rated conditional short-circuit current, type 2, 400 V : – A
  • Rated operation current at AC-3, 400 V : 16 A
  • Rated conditional short-circuit current, type 2, 230 V : – A
  • Rated conditional short-circuit current, type 1, 480 Y/277 V : – A
  • Coordination class according to IEC 60947-4-3 : Class 2
  • Rated operation current Ie : – A
  • Rated operation power at AC-3, 230 V, 3-phase : – kW
  • Rated power, 460 V, 60 Hz, 3-phase : – kW
  • Rated power, 575 V, 60 Hz, 3-phase : – kW
  • Width : 65 mm
  • Height : 290 mm
  • Rated operation power at AC-3, 400 V : 7.5 kW
  • Depth : 150 mm
  • Overload release current setting : 2.4 – 16 A
  • Rated control supply voltage Us at AC 50HZ : – V
  • Rated control supply voltage Us at AC 60HZ : – V
  • Rated control supply voltage Us at DC : 21.6 – 26.4 V