ET 200pro ASm Disconnecting Module, 400 V, Up To 25 A, Disconnection Up To Cat. 3/4 Han Q4/2

£545.39 inc VAT £454.49 ex VAT

SKU: 1050439011 Category: Tags: , ,

Description

Detail

ET 200pro ASm 400 V Disconnection module 400 V to 25 A for safe switching-off up to Category 3/4 Han Q4/2 Motor starters SIMATIC ET 200pro for operational switching of three-phase motors in the field, with short-circuit and overload protection and for fully TIA-integrated, highly automated applications, for example in conveyor systems. The multifunctional motor starters are fully integrated in the ET 200pro distributed I/O system. The fast and comprehensive configuration takes place in the TIA Portal. Cabinet-free use, thanks to the high IP65/67 degree of protection. Integrated communication via PROFIBUS and PROFINET. Thanks to the wide setting range, there is less variety of devices which means reduced costs for stock keeping and configuration. The easy installation by means of a wiring bus and plug-in technology facilitates fast replacement of the motor starters and increases the availability of the plant. The Motor Starter ES software is available for configuration, commissioning, operation and diagnostics. PROFIenergy supports active and efficient energy management. The devices are approved for worldwide use (e.g. IEC, CCC and UL/CSA) and are IE3/IE4-ready. Available as direct-on-line or reversing starter with various motor current ranges, as standard or High-Feature versions (including soft start function). As an option, a repair switch module can be used in order to guarantee a secure isolation for all downstream motor starters in the event of repair work. In addition, there is a fail-safe repair switch and a disconnecting module for fail-safe applications. ET 200pro motor starters – compact and smart.

Specification

  • Supporting protocol for PROFIBUS : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for PROFIsafe : No
  • Temperature compensated overload protection : No
  • With transformer : No
  • Suitable for emergency stop : No
  • Supporting protocol for SafetyBUS p : No
  • Supporting protocol for LON : No
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for ASI : No
  • Rated control supply voltage Us at DC : 20.4 – 28.8 V
  • Supporting protocol for CAN : No
  • Supporting protocol for INTERBUS : No
  • Supporting protocol for MODBUS : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for SUCONET : No
  • Supporting protocol for other bus systems : No
  • External reset possible : No
  • Rail mounting possible : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for INTERBUS-Safety : No
  • With short-circuit release : No
  • Rated operation current Ie : 25 A
  • Type of electrical connection of main circuit : Flat plug-in connection
  • Coordination class according to IEC 60947-4-3 : Class 1
  • Degree of protection (IP) : IP65
  • Number of command positions : –
  • Number of auxiliary contacts as normally open contact : –
  • Number of indicator lights : –
  • Number of auxiliary contacts as normally closed contact : –
  • Ambient temperature, upper operating limit : – °C
  • Rated conditional short-circuit current, type 2, 400 V : – A
  • Rated conditional short-circuit current, type 2, 230 V : – A
  • Rated operation current at AC-3, 400 V : 25 A
  • Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
  • Rated conditional short-circuit current, type 1, 480 Y/277 V : – A
  • Voltage type for actuating : DC
  • Rated operation power at AC-3, 230 V, 3-phase : – kW
  • Rated power, 460 V, 60 Hz, 3-phase : – kW
  • Rated operation power at AC-3, 400 V : – kW
  • Rated power, 575 V, 60 Hz, 3-phase : – kW
  • Width : 110 mm
  • Height : 230 mm
  • Depth : 150 mm
  • Rated control supply voltage Us at AC 50HZ : – V
  • Overload release current setting : 25 – 25 A
  • Rated control supply voltage Us at AC 60HZ : – V
  • Supporting protocol for AS-Interface Safety at Work : No
  • With fuse : No