Description
Detail
DS1E-X for ET200S High Feature DOL starter Setting range 2.4…8 A Mechanical switching Electronic protection AC-3, up to 3 kW / 400 V expandable for Brake control module 2DI module 2DI module Motor starter ES Circuit breaker signaling parameterizable DPV 1-capable PROFIENERGY-capable to PN The ET 200S distributed I/O is superseded by the new ET 200SP system.
Specification
Supporting protocol for other bus systems : No
Suitable for emergency stop : No
Supporting protocol for TCP/IP : No
With transformer : No
Supporting protocol for LON : No
Supporting protocol for ASI : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for MODBUS : No
Supporting protocol for Data-Highway : No
Supporting protocol for DeviceNet : No
Supporting protocol for SUCONET : No
External reset possible : No
Temperature compensated overload protection : No
Rail mounting possible : No
Supporting protocol for SERCOS : No
Supporting protocol for INTERBUS-Safety : No
With short-circuit release : Yes
With fuse : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
Voltage type for actuating : DC
Type of electrical connection of main circuit : Screw connection
Kind of motor starter : Direct starter
Coordination class according to IEC 60947-4-3 : Class 2
Number of command positions : –
Number of auxiliary contacts as normally open contact : –
Number of indicator lights : –
Number of auxiliary contacts as normally closed contact : –
Ambient temperature, upper operating limit : – °C
Rated conditional short-circuit current, type 2, 400 V : – A
Rated conditional short-circuit current, type 2, 230 V : – A
Rated operation current at AC-3, 400 V : 8 A
Rated conditional short-circuit current, type 1, 480 Y/277 V : – A
Degree of protection (IP) : IP20
Rated operation current Ie : – A
Rated operation power at AC-3, 230 V, 3-phase : – kW
Rated power, 460 V, 60 Hz, 3-phase : – kW
Rated power, 575 V, 60 Hz, 3-phase : – kW
Rated operation power at AC-3, 400 V : 3 kW
Width : 65 mm
Height : 290 mm
Overload release current setting : 2.4 – 8 A
Rated control supply voltage Us at AC 50HZ : – V
Depth : 150 mm
Rated control supply voltage Us at AC 60HZ : – V
Rated control supply voltage Us at DC : 20.4 – 28.8 V