Circuit Breaker 3Va2 Iec Frame 1000 Break 3VA2580-6HL32-0AA0

£3,591.30 inc VAT £2,992.75 ex VAT

Description

Detail

circuit breaker 3VA2 IEC frame 1000 breaking capacity class H Icu=85kA @ 415V 3-pole, line protection ETU320, LI, In=800A overload protection Ir=320A…800A short-circuit protection Ii=1.5…12 x In nut keeper kit 3VA2 molded-case circuit breaker with 8-series ETU for system protection. As an important element of SENTRON protective components for industrial and infrastructure applications, the 3VA molded-case circuit breakers from Siemens provide effective plant, starter and motor protection thanks to reliable shutdown in the event of an overload or short circuit. The 3VA molded-case circuit breakers set new standards in flexibility and the variety of modular accessories available. Standardized accessories for several sizes across all series of the 3VA1 and 3VA2 molded-case circuit breakers. Key features of this version of the 3VA molded-case circuit breaker: 1. Compact design. 2. Available as version for plant protection and generator protection. 3. Available as 3-pole and 4-pole version. 4. Four breaking capacity classes from 55ákA to 150ákA at 415áV. 5. Depending on the size: Rated current 25áA. 630áA. 6. Can be installed fixed, in plug-in design or as withdrawable version. 7. The series has a solid-state overcurrent trip unit. 8. Integrated display for measured values. 9. Integrated measuring function and optional communication connection via Modbus TCP, Modbus RTU, PROFINET and PROFIBUS. 10. Modular and easy-to-fit internal accessories with wide range of functions.

  • · MCCB_IEC_FS1000_800A_3P_85kA_ETU3_LI

Specification

  • Rated short-circuit breaking capacity lcu at 400 V, 50 Hz : 85 kA
  • Motor drive optional : No
  • Motor drive integrated : No
  • Integrated earth fault protection : No
  • Complete device with protection unit : Yes
  • DIN rail (top hat rail) mounting optional : Yes
  • With switched-off indicator : No
  • With under voltage release : No
  • Suitable for DIN rail (top hat rail) mounting : Yes
  • Adjustment range undelayed short-circuit release : 1200 – 8000 A
  • Device construction : Built-in device fixed built-in technique
  • Rated permanent current Iu : 800 A
  • Number of auxiliary contacts as normally open contact : 0
  • Degree of protection (IP) : IP40
  • Number of auxiliary contacts as normally closed contact : 0
  • Position of connection for main current circuit : Front side
  • Number of poles : 3
  • Number of auxiliary contacts as change-over contact : 0
  • Type of control element : Rocker lever
  • Type of electrical connection of main circuit : Screw connection