ATS48D88Q Soft Starter 88A 230/240V

£2,600.64 inc VAT £2,167.20 ex VAT

SKU: 2500152546 Category: Tags: ,

Description

Detail

Schneider Electric ATS48D88Q soft starter for asynchronous motor. It supports 45kW at 400V (connection in the motor supply line) for standard applications

  • · This Altistart 48 soft start/soft stop unit is a controller with 6 thyristors used for torque-controlled soft starting and stopping of three-phase asynchronous motors.
  • · It offers soft starting and deceleration functions along with machine and motor protection functions, as well as functions for communicating with control systems.
  • · It works at a rated supply voltage from 230V to 415V AC and up to 88A rating.
  • · Altistart 48 torque control enables starting without mechanical stress and smooth control of hydraulic transitions, with a single acceleration ramp making adjustments is quick and easy, whatever the load.
  • · If connected in the motor supply line it is suitable for motors with power rating up to 45kW (at 400V) for standards applications and 37kW (at 400V) for severe applications.
  • · If connected to the motor delta terminals it is suitable for motors with power rating up to 75kW (at 400V) for standards applications and 55kW (at 400V) for severe applications.
  • · It weighs 8.3kg and its dimensions are, 190mm wide, 290mm high, 235mm deep.
  • · 75A (connection in the motor supply line) for severe applications
  • · It is designed for use in the most common applications for centrifugal machines, pumps, fans, compressors and conveyors, which are primarily to be found in the construction, food and beverage and chemical industries.
  • · It complies with IEC/EN 60947-4-2 standard and is certified CE, UL, CSA, DNV, C-Tick, GOST, CCC, NOM, SEPRO, and TCF.

Specification

  • Degree of protection (IP) : IP20
  • Voltage type for actuating : AC
  • Rated surrounding temperature without derating : 40 °C
  • Rated power three-phase motor, inline, at 230 V : 22 kW
  • Rated power three-phase motor, inline, at 400 V : 45 kW
  • Rated power three-phase motor, inside delta, at 400 V : 75 kW
  • Rated operation current Ie at 40 °C Tu : 88 A
  • Rated power three-phase motor, inside delta, at 230 V : 45 kW
  • Rated control supply voltage Us at AC 50HZ : 220 – 415 V
  • Rated control supply voltage Us at AC 60HZ : 220 – 415 V
  • Rated control supply voltage Us at DC : 0 – 0 V
  • Rated operating voltage Ue : 230 – 415 V
  • Internal bypass : No
  • With display : No
  • Torque control : Yes
  • Integrated motor overload protection : Yes