Schneider Electric ATS48C17Q soft starter for asynchronous motor. It supports 45kW at 230V (connection in the motor supply line) for standard applications

  • · This Altistart 48 soft start/soft stop unit is a controller with 6 thyristors used for torque-controlled soft starting and stopping of three-phase asynchronous motors.
  • · It offers soft starting and deceleration functions along with machine and motor protection functions, as well as functions for communicating with control systems.
  • · It works at a rated supply voltage from 230V to 415V AC and up to 170A rating.
  • · Altistart 48 torque control enables starting without mechanical stress and smooth control of hydraulic transitions, with a single acceleration ramp making adjustments is quick and easy, whatever the load.
  • · If connected in the motor supply line it is suitable for motors with power rating up to 90kW (at 400V) for standards applications and 75kW (at 400V) for severe applications.
  • · If connected to the motor delta terminals it is suitable for motors with power rating up to 132kW (at 400V) for standards applications and 110kW (at 400V) for severe applications.
  • · It weighs 12.4kg and its dimensions are, 200mm wide, 340mm high, 265mm deep.
  • · 242A (connection to the motor delta terminals) for severe applications
  • · It is designed for use in the most common applications for centrifugal machines, pumps, fans, compressors and conveyors, which are primarily to be found in the construction, food and beverage and chemical industries.
  • · It complies with IEC/EN 60947-4-2 standard and is certified CE, UL, CSA, DNV, C-Tick, GOST, CCC, NOM, SEPRO, and TCF.

Specification

  • Degree of protection (IP) : IP20
  • Voltage type for actuating : AC
  • Rated operation current Ie at 40 °C Tu : 170 A
  • Rated power three-phase motor, inside delta, at 400 V : 132 kW
  • Rated surrounding temperature without derating : 40 °C
  • Rated power three-phase motor, inline, at 230 V : 45 kW
  • Rated power three-phase motor, inline, at 400 V : 90 kW
  • Rated power three-phase motor, inside delta, at 230 V : 90 kW
  • Rated control supply voltage Us at AC 50HZ : 220 – 415 V
  • Rated operating voltage Ue : 230 – 415 V
  • Rated control supply voltage Us at DC : 0 – 0 V
  • Rated control supply voltage Us at AC 60HZ : 220 – 415 V
  • With display : No
  • Internal bypass : No
  • Torque control : Yes
  • Integrated motor overload protection : Yes