Description
Detail
AS-i compact module K45 digital A/B slave 4 x (1 DI/1 DQ), IP67 4 x 1 input / 1 output 4 x M12 socket Total current for all inputs and outputs max. 500 mA Supply I/O from 24 V DC Mounting plate 3RK1901-2EA00 or 3RK1901-2DA00 is to be ordered separately
- · AS-Interface compact module K45, A/B slave (Spec. 3.0), IP67 digital, 4x (1 DI/1 DQ)
Specification
Short-circuit protection, outputs available : Yes
Front build in possible : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for SERCOS : No
Appendant operation agent (Ex ib) : No
Appendant operation agent (Ex ia) : No
System accessory : Yes
Fieldbus connection over separate bus coupler possible : No
Rail mounting possible : No
Rack-assembly possible : No
Supporting protocol for other bus systems : No
Supporting protocol for SUCONET : No
Supporting protocol for DeviceNet : No
Supporting protocol for Data-Highway : No
Supporting protocol for MODBUS : No
Supporting protocol for KNX : No
Supporting protocol for INTERBUS : No
Supporting protocol for CAN : No
Supporting protocol for PROFINET IO : No
Radio standard UMTS : No
Radio standard GSM : No
Radio standard GPRS : No
Digital outputs configurable : No
Digital inputs configurable : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for PROFIsafe : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFIBUS : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for DeviceNet Safety : No
IO link master : No
Supporting protocol for AS-Interface Safety at Work : No
Radio standard WLAN 802.11 : No
Radio standard Bluetooth : No
Wall mounting/direct mounting : No
Number of HW-interfaces serial TTY : 0
Number of HW-interfaces Wireless : 0
Number of digital inputs : 4
Number of interfaces PROFINET : 0
Number of HW-interfaces other : 0
Number of HW-interfaces parallel : 0
Number of HW-interfaces USB : 0
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces RS-485 : 0
Number of digital outputs : 4
Number of HW-interfaces industrial Ethernet : 0
Number of HW-interfaces RS-232 : 0
Degree of protection (IP) : IP67
Explosion safety category for gas : None
Explosion safety category for dust : None
Type of electric connection : Screw connection
Voltage type of supply voltage : DC
Type of output voltage : DC
Supply voltage AC 60 Hz : – – – V
Supporting protocol for ASI : Yes
Supporting protocol for TCP/IP : No
With optical interface : No
Supporting protocol for LON : No
Suitable for safety functions : No
Permitted voltage at input : – – – V
Permitted voltage at output : – – – V
Supply voltage DC : – – – V
Type of voltage (input voltage) : DC
Supply voltage AC 50 Hz : – – – V
Time delay at signal exchange : – – – ms
Depth : 30 mm
Height : 80 mm
Width : 45 mm
Input current at signal 1 : 6 mA
Output current : 0.5 A