Description
Detail
AS-i compact module K60 digital A/B slave, 8 DI/2 DQ, IP67 3 x 2 inputs and 2 x 1 input / 1 output max. 200 mA sensor supply Outputs 2 A, 24 V DC 8 x M12 sockets with Y assignment Mounting plate 3RK1901-0CA00 must be ordered separately
Specification
Rail mounting possible : No
Rack-assembly possible : No
Front build in possible : No
Supporting protocol for SERCOS : No
Supporting protocol for INTERBUS-Safety : No
Appendant operation agent (Ex ib) : No
System accessory : Yes
Appendant operation agent (Ex ia) : No
Fieldbus connection over separate bus coupler possible : No
Wall mounting/direct mounting : No
Short-circuit protection, outputs available : Yes
Supporting protocol for other bus systems : No
Supporting protocol for SUCONET : No
Supporting protocol for DeviceNet : No
Supporting protocol for Data-Highway : No
Supporting protocol for MODBUS : No
Supporting protocol for KNX : No
Supporting protocol for INTERBUS : No
Supporting protocol for PROFINET IO : No
Suitable for safety functions : No
Radio standard UMTS : No
Radio standard GSM : No
Radio standard GPRS : No
Digital outputs configurable : No
Digital inputs configurable : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for PROFIsafe : No
Supporting protocol for CAN : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for AS-Interface Safety at Work : No
IO link master : No
Radio standard WLAN 802.11 : No
Radio standard Bluetooth : No
Number of HW-interfaces RS-422 : 0
Number of digital outputs : 2
Number of HW-interfaces Wireless : 0
Number of interfaces PROFINET : 0
Number of HW-interfaces other : 0
Number of HW-interfaces USB : 0
Number of HW-interfaces parallel : 0
Number of HW-interfaces RS-485 : 0
Number of HW-interfaces serial TTY : 0
Number of digital inputs : 8
Number of HW-interfaces RS-232 : 0
Number of HW-interfaces industrial Ethernet : 0
Degree of protection (IP) : IP67
Explosion safety category for dust : None
Type of electric connection : Screw connection
Explosion safety category for gas : None
Voltage type of supply voltage : DC
Type of output voltage : DC
Supply voltage DC : – – – V
Supporting protocol for PROFIBUS : No
Supporting protocol for ASI : Yes
Supporting protocol for TCP/IP : No
With optical interface : No
Supporting protocol for LON : No
Time delay at signal exchange : – – – ms
Permitted voltage at input : – – – V
Permitted voltage at output : – – – V
Type of voltage (input voltage) : DC
Supply voltage AC 60 Hz : – – – V
Supply voltage AC 50 Hz : – – – V
Depth : 29 mm
Height : 152 mm
Width : 60 mm
Input current at signal 1 : 6 mA
Output current : 2 A