Description
Detail
Schneider Electric ATV212WU75N4C Altivar 212 7.5kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 3 IEC 61800-5-1 pollution degree.
- · Current Rating: 16A
- · Height: 340mm
- · Range: Altivar 212
- · Width: 230mm
- · Weight: 11.85kg
- · For Use With Motor: ATV212 Asynchronous
- · Depth: 208mm
- · IP Rating: IP55
- · Supply Voltage: 380 to 480V
Specification
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for MODBUS : Yes
Supporting protocol for PROFIBUS : No
Supporting protocol for ASI : No
Supporting protocol for KNX : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
With control unit : Yes
Supporting protocol for LON : Yes
Supporting protocol for Data-Highway : No
Supporting protocol for SUCONET : No
Supporting protocol for other bus systems : Yes
Supporting protocol for SERCOS : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for DeviceNet : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for DeviceNet Safety : No
With PC connection : Yes
Supporting protocol for Foundation Fieldbus : No
4-quadrant operation possible : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Integrated breaking resistance : No
Application in domestic- and commercial area permitted : Yes
Application in industrial area permitted : Yes
Number of HW-interfaces USB : 0
Number of phases output : 3
Number of phases input : 3
Type of converter : I converter
Number of interfaces PROFINET : 0
Mains frequency : 50/60 Hz
Number of HW-interfaces parallel : 0
Number of HW-interfaces RS-232 : 0
Relative symmetric net voltage tolerance : 0 %
Number of HW-interfaces serial TTY : 0
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces industrial Ethernet : 0
Number of HW-interfaces RS-485 : 1
Max. output at quadratic load at rated output voltage : 0 kW
Degree of protection (IP) : IP55
Width : 230 mm
Number of HW-interfaces other : 0
Nominal output current I2N : 16 A
Depth : 208 mm
Max. output frequency : 200 Hz
Height : 340 mm
Max. output at linear load at rated output voltage : 7.5 kW
Max. output voltage : 480 V
Relative symmetric net frequency tolerance : 5 %
Mains voltage : 380 – 480 V
Supporting protocol for TCP/IP : No
With optical interface : No