Schneider Electric ATV212HD55N4 Altivar 212 55kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 3 IEC 61800-5-1 pollution degree.
- · Current Rating: 116A
- · Height: 630mm
- · Range: Altivar 212
- · Width: 320mm
- · For Use With Motor: ATV212 Asynchronous
- · Depth: 290mm
- · IP Rating: IP20 & IP41 (Upper Part), IP21
- · Supply Voltage: 380 to 480V
Specification
Supporting protocol for AS-Interface Safety at Work : No
With control unit : Yes
Supporting protocol for LON : Yes
Supporting protocol for DeviceNet : No
Supporting protocol for MODBUS : Yes
Supporting protocol for CAN : No
With optical interface : No
Supporting protocol for KNX : No
Supporting protocol for INTERBUS : No
Supporting protocol for Data-Highway : No
Supporting protocol for SUCONET : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for SERCOS : No
Supporting protocol for other bus systems : Yes
Supporting protocol for ASI : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFINET IO : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for Foundation Fieldbus : No
With PC connection : Yes
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
4-quadrant operation possible : No
Integrated breaking resistance : No
Application in domestic- and commercial area permitted : Yes
Application in industrial area permitted : Yes
Number of HW-interfaces industrial Ethernet : 0
Number of phases output : 3
Number of phases input : 3
Type of converter : I converter
Degree of protection (IP) : IP21
Number of HW-interfaces parallel : 0
Number of HW-interfaces serial TTY : 0
Max. output at quadratic load at rated output voltage : 0 kW
Number of HW-interfaces USB : 0
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces RS-485 : 1
Number of HW-interfaces RS-232 : 0
Relative symmetric net voltage tolerance : 0 %
Number of interfaces PROFINET : 0
Mains frequency : 50/60 Hz
Number of HW-interfaces other : 0
Depth : 290 mm
Nominal output current I2N : 116 A
Width : 320 mm
Height : 630 mm
Max. output at linear load at rated output voltage : 55 kW
Max. output voltage : 480 V
Relative symmetric net frequency tolerance : 5 %
Max. output frequency : 200 Hz
Mains voltage : 380 – 480 V
Supporting protocol for PROFIBUS : No
Supporting protocol for TCP/IP : No