Description
Detail
Schneider Electric ATV212WU40N4C Altivar 212 4kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 3 IEC 61800-5-1 pollution degree.
- · Current Rating: 9.1A
- · Height: 340mm
- · Range: Altivar 212
- · Width: 230mm
- · Weight: 10.55kg
- · For Use With Motor: ATV212 Asynchronous
- · Depth: 208mm
- · IP Rating: IP55
- · Supply Voltage: 380 to 480V
Specification
Supporting protocol for SERCOS : No
Supporting protocol for DeviceNet : No
Supporting protocol for ASI : No
Supporting protocol for CAN : No
Supporting protocol for KNX : No
Supporting protocol for INTERBUS : No
Supporting protocol for MODBUS : Yes
With control unit : Yes
Supporting protocol for LON : Yes
Supporting protocol for Data-Highway : No
Supporting protocol for SUCONET : No
Supporting protocol for other bus systems : Yes
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for AS-Interface Safety at Work : No
With optical interface : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
4-quadrant operation possible : No
With PC connection : Yes
Supporting protocol for PROFINET IO : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for PROFIsafe : No
Integrated breaking resistance : No
Application in domestic- and commercial area permitted : Yes
Application in industrial area permitted : Yes
Number of HW-interfaces industrial Ethernet : 0
Number of phases input : 3
Mains frequency : 50/60 Hz
Number of phases output : 3
Number of HW-interfaces parallel : 0
Type of converter : I converter
Max. output at quadratic load at rated output voltage : 0 kW
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces USB : 0
Number of HW-interfaces RS-232 : 0
Number of HW-interfaces RS-485 : 1
Number of HW-interfaces serial TTY : 0
Relative symmetric net voltage tolerance : 0 %
Number of interfaces PROFINET : 0
Degree of protection (IP) : IP55
Number of HW-interfaces other : 0
Width : 230 mm
Height : 340 mm
Depth : 208 mm
Max. output voltage : 480 V
Max. output at linear load at rated output voltage : 4 kW
Relative symmetric net frequency tolerance : 5 %
Max. output frequency : 200 Hz
Nominal output current I2N : 9.1 A
Mains voltage : 380 – 480 V
Supporting protocol for PROFIBUS : No
Supporting protocol for TCP/IP : No