Altivar Variable Speed Drive ATV212 3-Phase 3kW 4HP 480V EMC IP21

£767.59 inc VAT £639.66 ex VAT

Description

Detail

Schneider Electric ATV212HU30N4 Altivar 212 3kW variable speed drive for pumps and fans in HV AC incorporates flux vector control without sensor, standard asynchronous motor control profile. APOGEE FLN, BACnet, LonWorks, METASYS N2 and Modbus communication port protocol. 40 to 50°C with derating factor operating temperature. Conforms to 3 IEC 61800-5-1 pollution degree.

  • · Current Rating: 7.2A
  • · Height: 184mm
  • · Range: Altivar 212
  • · Width: 142mm
  • · Weight: 3.35kg
  • · For Use With Motor: ATV212 Asynchronous
  • · Depth: 150mm
  • · IP Rating: IP20 & IP41 (Upper Part), IP21
  • · Supply Voltage: 380 to 480V

Specification

  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for ASI : No
  • Supporting protocol for other bus systems : Yes
  • Supporting protocol for PROFIBUS : No
  • Supporting protocol for INTERBUS : No
  • Supporting protocol for TCP/IP : No
  • Supporting protocol for Data-Highway : No
  • Supporting protocol for MODBUS : Yes
  • Supporting protocol for SUCONET : No
  • With control unit : Yes
  • Supporting protocol for DeviceNet : No
  • Supporting protocol for SERCOS : No
  • Supporting protocol for LON : Yes
  • With PC connection : Yes
  • Supporting protocol for KNX : No
  • Supporting protocol for INTERBUS-Safety : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for SafetyBUS p : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for PROFIsafe : No
  • 4-quadrant operation possible : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for Foundation Fieldbus : No
  • Application in domestic- and commercial area permitted : Yes
  • Supporting protocol for PROFINET IO : No
  • Integrated breaking resistance : No
  • Application in industrial area permitted : Yes
  • Number of HW-interfaces industrial Ethernet : 0
  • Number of phases output : 3
  • Type of converter : I converter
  • Number of phases input : 3
  • Degree of protection (IP) : IP21
  • Number of HW-interfaces parallel : 0
  • Number of HW-interfaces serial TTY : 0
  • Number of HW-interfaces RS-422 : 0
  • Number of HW-interfaces USB : 0
  • Max. output at quadratic load at rated output voltage : 0 kW
  • Number of HW-interfaces RS-485 : 1
  • Number of interfaces PROFINET : 0
  • Number of HW-interfaces RS-232 : 0
  • Relative symmetric net voltage tolerance : 0 %
  • Mains frequency : 50/60 Hz
  • Number of HW-interfaces other : 0
  • Width : 142 mm
  • Depth : 150 mm
  • Height : 184 mm
  • Max. output voltage : 480 V
  • Max. output at linear load at rated output voltage : 3 kW
  • Max. output frequency : 200 Hz
  • Nominal output current I2N : 7.2 A
  • Relative symmetric net frequency tolerance : 5 %
  • Mains voltage : 380 – 480 V
  • With optical interface : No
  • Supporting protocol for CAN : No