Advanced control unit LUCD, class 20, 4,5…18A, 110…220 V DC/AC

£191.10 inc VAT £159.25 ex VAT

Description

Detail

Advanced control unit LUCD, class 20, 4,5…18A, 110…220 V DC/AC. range: TeSys – product name: TeSys U – device short name: LUCD – product specific application: basic protection and advanced functions, communication – product compatibility: LUFC00, LUFDA01, LUFDA10, LUFDH11, LUFN.., LUFV2, LUFW10 – utilisation category: AC-41, AC-43, AC-44 – motor power kW: 15 kW at 690 V AC 50/60 Hz, 7.5 kW at 400…440 V AC 50/60 Hz, 9 kW at 500 V AC 50/60 Hz – [Uc] control circuit voltage: 110…220 V DC, 110…240 V AC – thermal overload class: class 20 – frequency limit: 40…60 Hz – temperature compensation: -25…70 °C – conforming to IEC 60947-6-2, class 20 – frequency limit: 40…60 Hz – temperature compensation: -25…70 °C – conforming to UL 508.

Specification

  • With fuse : No
  • Supporting protocol for PROFIBUS : Yes
  • Supporting protocol for Data-Highway : No
  • External reset possible : Yes
  • Supporting protocol for SUCONET : No
  • Supporting protocol for DeviceNet : Yes
  • Supporting protocol for LON : No
  • Supporting protocol for other bus systems : Yes
  • Rail mounting possible : No
  • Supporting protocol for AS-Interface Safety at Work : No
  • Supporting protocol for INTERBUS-Safety : No
  • Supporting protocol for ASI : Yes
  • Supporting protocol for SERCOS : No
  • With short-circuit release : Yes
  • Supporting protocol for PROFIsafe : No
  • Supporting protocol for DeviceNet Safety : No
  • Supporting protocol for Foundation Fieldbus : No
  • Supporting protocol for PROFINET CBA : No
  • Supporting protocol for EtherNet/IP : No
  • Supporting protocol for PROFINET IO : No
  • Supporting protocol for SafetyBUS p : No
  • Temperature compensated overload protection : Yes
  • Number of indicator lights : 0
  • Voltage type for actuating : AC/DC
  • Degree of protection (IP) : IP20
  • Number of auxiliary contacts as normally open contact : 0
  • Number of command positions : 0
  • Rated operation current Ie : 18 A
  • Rated operation current at AC-3, 400 V : 18 A
  • Rated operation power at AC-3, 400 V : 7.5 kW
  • Ambient temperature, upper operating limit : 70 °C
  • Number of auxiliary contacts as normally closed contact : 0
  • Rated control supply voltage Us at AC 50HZ : 110 – 240 V
  • Release class : CLASS 20
  • Overload release current setting : 4.5 – 18 A
  • Rated control supply voltage Us at AC 60HZ : 110 – 240 V
  • With transformer : No
  • Supporting protocol for MODBUS : Yes
  • Rated control supply voltage Us at DC : 110 – 220 V
  • Supporting protocol for TCP/IP : No
  • Suitable for emergency stop : No
  • Supporting protocol for CAN : Yes
  • Supporting protocol for INTERBUS : No