3LD Switch Disconnector, Emergency Stop Switch, 3-Pole, Iu: 100 A, …

£137.02 inc VAT £114.18 ex VAT

Description

Detail

SENTRON, Switch disconnector 3LD, emergency switching-off switch, 3- pole, Iu: 100 A, operating power / at AC-23 A 400 V: 37 kW, front-mounted, rotary operating mechanism, Red / yellow, 4-hole mounting of the handle The 3LD main and emergency off switch for safe disconnection of loads in a wide variety of environments. There are numerous possible applications for the 3LD3 disconnector units. After disconnects from the grid, they ensure safe activation of all of the electrical equipment, thus switch, for example, to three-phase motors, but also air-conditioning and ventilation systems. 3LD3 are also ideal for control panels, in particular for applications in small machines (for example saws, compressors, pumps, concrete mixers, drills, mills, and woodworking machinery) Key features of the Siemens 3LD main and emergency off switches: 1. Modular design, fast and easy mounting of auxiliary switches, N-PE terminal, or 4-pole 2. Versatile thanks to local approvals. 3. One mechanical size for five electrical sizes. 4. Can be used for DC applications. 5. Types of mounting: Front mounting, mounting plate, standard mounting rail. 6. Optimized disconnect from 16 A to 63 A with lockable rotary operating mechanism.

Specification

  • Suitable for front mounting 4-hole : Yes
  • Max. rated operation voltage Ue AC : 690 V
  • Rated operating voltage : – V
  • Interlockable : Yes
  • Version as emergency stop installation : Yes
  • Version as main switch : Yes
  • Version as safety switch : Yes
  • Version as maintenance-/service switch : Yes
  • Suitable for ground mounting : No
  • Rated operation power at AC-23, 400 V : 37 kW
  • Motor drive integrated : No
  • Suitable for front mounting centre : No
  • Suitable for distribution board installation : No
  • Suitable for intermediate mounting : No
  • Motor drive optional : No
  • Voltage release optional : No
  • Version as reversing switch : No
  • Number of auxiliary contacts as normally closed contact : 0
  • Colour control element : Red
  • Type of electrical connection of main circuit : Frame clamp
  • Device construction : Built-in device fixed built-in technique
  • Degree of protection (IP), front side : IP65
  • Number of auxiliary contacts as change-over contact : 0
  • Number of switches : 1
  • Number of auxiliary contacts as normally open contact : 0
  • Number of poles : 3
  • Type of control element : Short thumb-grip
  • Rated permanent current at AC-21, 400 V : 100 A
  • Rated permanent current at AC-23, 400 V : 70 A
  • Rated short-time withstand current lcw : 2 kA
  • Rated permanent current Iu : 100 A
  • Conditioned rated short-circuit current Iq : – kA
  • Switching power at 400 V : – kW
  • Rated operation power at AC-3, 400 V : 30 kW