Description
Detail
Reversing starter, 3RM1, 500 V, 0.55 – 3 kW, 1.6 – 7 A, 110-230 V AC, screw terminals Reversing starter SIRIUS 3RM1 for functional switching of three-phase motors. Narrow design, multifunctional, with electronic overload protection, durable and energy-efficient hybrid switching technology, small number of different devices due to wide setting ranges, easy installation thanks to low wiring requirements, fast error diagnostics due to LED display, innovative enclosure concept, e.g. with labeled cover caps and removable terminals. Available as direct or reversing starter, optionally with ATEX certification and safety-related shutdown, with various motor current ranges, supply voltage types and connection technologies. An extensive range of accessories, such as device connector, fuse module, infeed system or sealable covers, completes the system. Getting started in minimum space – SIRIUS 3RM1 motor starters.
Specification
Rail mounting possible : Yes
Suitable for emergency stop : No
Supporting protocol for LON : No
Supporting protocol for TCP/IP : No
Supporting protocol for ASI : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for MODBUS : No
Supporting protocol for Data-Highway : No
Supporting protocol for DeviceNet : No
Supporting protocol for SUCONET : No
Supporting protocol for other bus systems : No
External reset possible : Yes
With transformer : No
Supporting protocol for SERCOS : No
Supporting protocol for INTERBUS-Safety : No
With short-circuit release : No
With fuse : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Temperature compensated overload protection : No
Rated conditional short-circuit current, type 1, 600 Y/347 V : – A
Degree of protection (IP) : IP20
Type of electrical connection for auxiliary- and control current circuit : Screw connection
Type of electrical connection of main circuit : Screw connection
Voltage type for actuating : AC/DC
Number of command positions : 0
Number of auxiliary contacts as normally open contact : 1
Number of auxiliary contacts as normally closed contact : 1
Number of indicator lights : 4
Ambient temperature, upper operating limit : 50 °C
Rated conditional short-circuit current, type 2, 400 V : – A
Rated conditional short-circuit current, type 2, 230 V : – A
Rated operation current at AC-3, 400 V : 7 A
Rated conditional short-circuit current, type 1, 480 Y/277 V : – A
Release class : CLASS 10 A
Rated operation current Ie : 7 A
Rated operation power at AC-3, 230 V, 3-phase : 1.5 kW
Rated power, 575 V, 60 Hz, 3-phase : – kW
Rated power, 460 V, 60 Hz, 3-phase : 2.2065 kW
Rated operation power at AC-3, 400 V : 3 kW
Width : 22.5 mm
Height : 100 mm
Depth : 141.6 mm
Overload release current setting : 7 – 7 A
Rated control supply voltage Us at AC 50HZ : 110 – 230 V
Rated control supply voltage Us at AC 60HZ : 110 – 230 V
Rated control supply voltage Us at DC : 110 – 110 V