Detail

Circuit breaker size S0 for system protection with approval circuit breaker UL 489, CSA C22.2 No.5-02 A-release 22 A N-release 286 A screw terminal Standard switching capacity Circuit breaker SIRIUS 3RV2 For system protection according to UL 489/CSA C22.2 No. 5 for the short-circuit protection of systems and loads in plants configured in accordance with UL. Thanks to their low heat loss, the compact and climate-resistant circuit breakers are optimized for use in load feeders, and also for IE3/IE4 motors, of course, and equally for the switching of direct current. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date – SIRIUS modular system.

  • · CIRCUIT-BREAKER UL489 22A

Specification

  • Adjustment range short-term delayed short-circuit release : – – – A
  • Motor drive optional : No
  • Motor drive integrated : No
  • With under voltage release : No
  • With switched-off indicator : No
  • Suitable for DIN rail (top hat rail) mounting : No
  • Integrated earth fault protection : No
  • Complete device with protection unit : Yes
  • DIN rail (top hat rail) mounting optional : Yes
  • Rated voltage : 20 – 690 V
  • Adjustment range undelayed short-circuit release : 286 – 286 A
  • Degree of protection (IP) : IP20
  • Rated short-circuit breaking capacity lcu at 400 V, 50 Hz : 55 kA
  • Rated permanent current Iu : 22 A
  • Number of poles : 3
  • Number of auxiliary contacts as normally closed contact : 0
  • Number of auxiliary contacts as normally open contact : 0
  • Number of auxiliary contacts as change-over contact : 0
  • Device construction : Built-in device fixed built-in technique
  • Type of electrical connection of main circuit : Screw connection
  • Type of control element : Toggle