Circuit Breaker Size S3 For Motor Protection C 3RV2042-4MB10

£704.46 inc VAT £587.05 ex VAT

SKU: 2501252307 Category: Tags: ,

Description

Detail

Circuit breaker size S3 for motor protection, Class 20 A-release 80…100 A N-release 1300 A screw terminal Increased switching capacity 100 kA Circuit breaker SIRIUS 3RV2 For motor protection for the reliable shutdown in the event of a short-circuit and for protecting the loads and system against overload, and for safe isolation of the system from the network. Thanks to their low heat loss, the compact and climate-resistant circuit breakers are optimized for use in load feeders, and also for IE3/IE4 motors, of course, and equally for the switching of direct current. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date – SIRIUS modular system.

  • · Circuit breaker, S3, motor protection, Class 20 A release 80-100 A short-circuit release 1300 A

Specification

  • Height : 165 mm
  • With integrated under voltage release : No
  • Phase failure sensitive : Yes
  • With integrated auxiliary switch : No
  • With thermal protection : Yes
  • Rated operating voltage : 690 – 690 V
  • Overload release current setting : 80 – 100 A
  • Adjustment range undelayed short-circuit release : 1300 – 1300 A
  • Depth : 176 mm
  • Rated operation power at AC-3, 230 V : 30 kW
  • Switch off technique : Magnetic
  • Width : 70 mm
  • Rated operation power at AC-3, 400 V : 45 kW
  • Rated short-circuit breaking capacity lcu at 400 V, AC : 100 kA
  • Rated permanent current Iu : 100 A
  • Device construction : Built-in device fixed built-in technique
  • Number of poles : 3
  • Type of control element : Turn button
  • Degree of protection (IP) : IP20
  • Type of electrical connection of main circuit : Screw connection