Circuit Breaker, S00 For Transformer Protection A-Release 11-16 A, Short-Circuit Release 286 A

£146.71 inc VAT £122.26 ex VAT

SKU: 1050443149 Category: Tags: ,

Description

Detail

Circuit breaker size S00 for transformer protection A-release 10…16 A N-release 286 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC Circuit breaker SIRIUS 3RV2 For transformer protection for the reliable protection of transformers against short-circuit and overload. Thanks to their low heat loss, the compact and climate-resistant circuit breakers are optimized for use in load feeders, and also for IE3/IE4 motors, of course, and equally for the switching of direct current. Worldwide approvals (e.g. IEC and UL/CSA) and applications in hazardous areas (ATEX or IEC Ex) are a matter of course. Device versions are available for motor protection (also with overload relay function), plant protection, short-circuit protection of starter combinations, transformer protection, as main and EMERGENCY OFF switches and for use in IT networks. They are available with screw or spring-type terminals for fast, maintenance-free and vibration-proof connection, and optionally with integral auxiliary switch. The comprehensive range of accessories, such as auxiliary switches, auxiliary releases, signaling switches etc. is standardized for all sizes. The use of different energy infeed options, such as the associated SIRIUS 3RV29 infeed system, considerably reduces the main circuit wiring. The 3RV2 circuit breakers replace the well-proven 3RV1 series. Simple, efficient and always up to date – SIRIUS modular system.

  • · Circuit breaker, S00 for transformer protection A-release 11-16 A, short-circuit release 286 A

Specification

  • Rated voltage : 20 – 690 V
  • Complete device with protection unit : Yes
  • DIN rail (top hat rail) mounting optional : Yes
  • Motor drive optional : No
  • With under voltage release : No
  • Integrated earth fault protection : No
  • Suitable for DIN rail (top hat rail) mounting : No
  • With switched-off indicator : No
  • Motor drive integrated : No
  • Adjustment range undelayed short-circuit release : 286 – 286 A
  • Adjustment range short-term delayed short-circuit release : – – – A
  • Degree of protection (IP) : IP20
  • Overload release current setting : 10 – 16 A
  • Rated permanent current Iu : 16 A
  • Rated short-circuit breaking capacity lcu at 400 V, 50 Hz : 55 kA
  • Number of poles : 3
  • Number of auxiliary contacts as normally closed contact : 1
  • Number of auxiliary contacts as change-over contact : 0
  • Number of auxiliary contacts as normally open contact : 1
  • Device construction : Built-in device fixed built-in technique
  • Type of control element : Toggle
  • Type of electrical connection of main circuit : Screw connection